81284_1.book Page 1 Friday, May 4, 2007 7:29 AM ST70 Instrument User Reference Manual Document reference: 81284-1 Date: June 2007 www.Busse-Yachtshop.de info@busse-yachtshop.
81284_1.book Page 2 Friday, May 4, 2007 7:29 AM Raymarine, SeaTalk, SeaTalk2 and SeaTalkng are trademarks of Raymarine plc © Book contents copyright Raymarine plc www.Busse-Yachtshop.de info@busse-yachtshop.
81284_1.book Page i Friday, May 4, 2007 7:29 AM Contents i Contents Preface ........................................................................................................................... iii Safety notices ..........................................................................................................iii WARNING: Product installation & operation .................................. iii WARNING: Electrical safety.................................................................
81284_1.book Page ii Friday, May 4, 2007 7:29 AM ii ST70 Instrument User Reference Manual 2.2 Seatrial calibration ....................................................................................... 17 WARNING: Ensure you have sufficient sea room for calibration17 Preliminary procedures................................................................................. 18 Wind transducer setup.................................................................................. 18 Linearization ............
81284_1.book Page iii Friday, May 4, 2007 7:29 AM Preface iii Preface Contents Safety notices WARNING: Product installation & operation This equipment must be installed, commissioned and operated in accordance with the Raymarine instructions provided. Failure to do so could result in personal injury, damage to your boat and/or poor product performance. WARNING: Electrical safety Make sure you have switched off the power supply before you start installing this product.
81284_1.book Page iv Friday, May 4, 2007 7:29 AM iv ST70 Instrument User Reference Manual • Routine maintenance instructions • Troubleshooting instructions • ST70 Installation Guide. Describes how to fit an ST70 instrument and connect it to an operating system. Intended for installers. Additional information on Raymarine SeaTalkng systems is given in the SeaTalkng Reference Manual. To the best of our knowledge, the information in the product documents was correct when they went to press.
81284_1.book Page 1 Friday, May 4, 2007 7:29 AM Chapter 1: ST70 General Information 1 Chapter 1: ST70 General Information 1.1 ST70 Operating Principles The ST70 instrument repeats data from Raymarine SeaTalk, SeaTalk2 and SeaTalkng systems. The actual information available depends on what information is present on the system, i.e. what transducers are connected. The ST70 instrument displays information on individual operational pages.
1284_1.book Page 2 Friday, May 4, 2007 7:29 AM 2 ST70 Instrument User Reference Manual Setup functions In addition to the eight operational pages, setup menus and pages controlled by the front-panel buttons, enable you to access and change the instrument parameters. To choose option 1 press Menu Title 1 To choose option 3 press 2 3 Selected option Information box Press ENTER to select D10031-1 i Each setup menu provides a number of options.
81284_1.
81284_1.book Page 4 Friday, May 4, 2007 7:29 AM 4 ST70 Instrument User Reference Manual Normal operation A summary of the day-to-day operating and setup functions is shown in Figure 1-2: Normal operation. Detailed operating instructions are given in the ST70 Instrument Operating Guide.
81284_1.book Page 5 Friday, May 4, 2007 7:29 AM Chapter 1: ST70 General Information 5 Day-to-day setting up Instructions for setting up many of the ST70 Instrument parameters are given in the ST70 Instrument Operating Guide and are not repeated here. Other setup procedures are carried out during Commissioning to set: • Language. • Vessel Type. • Time format. • Date format.
81284_1.book Page 6 Friday, May 4, 2007 7:29 AM 6 ST70 Instrument User Reference Manual Power protocol Power to each individual ST70 instrument can be switched on and off using the power button (as described in the ST70 Operating Guide). However, where instruments are part of a system, it may be more convenient to switch power for the entire system from a central circuit breaker.
81284_1.book Page 7 Friday, May 4, 2007 7:29 AM Chapter 2: Commissioning Procedures 7 Chapter 2: Commissioning Procedures Before an ST70 instrument is used for the first time, it must be commissioned in accordance with the instructions in this chapter, to carry out: • Dockside setup followed by • Seatrial calibration. 2.
81284_1.book Page 8 Friday, May 4, 2007 7:29 AM 8 ST70 Instrument User Reference Manual Initial setup Select language Use < and > to select the required language, then press ENTER to display the ‘Welcome’ screen. When you are ready to proceed, press ENTER to display the Vessel Type menu. Vessel Type Vessel Type The Vessel Type menu enables you to automatically apply the optimum instrument settings for your vessel type.
81284_1.book Page 9 Friday, May 4, 2007 7:29 AM Chapter 2: Commissioning Procedures 9 Setting date format To set the required date format: 1. At the Time & Date setup menu, use < and > to select the Set date format option, then press ENTER, to display the Set date format page. Time & Date Press ENTER to select Time & Date Set date format Press ENTER to select 2. Use < and > to select the required Date Format, then press ENTER, to save the format and return to the Time & Date summary page. 3.
81284_1.book Page 10 Friday, May 4, 2007 7:29 AM 10 ST70 Instrument User Reference Manual Setting local time To set the instrument time to your local time. 1. At the Time & Date setup menu, use < and > to select the Set time offset option, then press ENTER, to display the Set time offset page. Time & Date Press ENTER to select 2. Use < and > to set the correct local time.
81284_1.book Page 11 Friday, May 4, 2007 7:29 AM Chapter 2: Commissioning Procedures 11 Check the information on the Units summary pages. With the second Units summary page displayed, press ENTER to display the Units setup menu. Units Continue Press ENTER to select If you want to change any data Units: 1. With the Units setup menu displayed, use < and > to select the type of data you want to change, i.e. Speed, Depth, Distance etc. D9980-1 If you want to accept all data Units as currently set: 1.
81284_1.book Page 12 Friday, May 4, 2007 7:29 AM 12 ST70 Instrument User Reference Manual WARNING: Ensure you use the correct depth offset The use of the correct depth offset is critical to the safety of the vessel. If an incorrect offset value is applied, this could result in misleading depth information being displayed with a consequent risk of running aground. Take great care to ensure you set the correct value.
81284_1.book Page 13 Friday, May 4, 2007 7:29 AM Chapter 2: Commissioning Procedures 13 Transducer Setup ST70 will now search the network for transducers. Press CANCEL to stop. Press ENTER to continue At the end of the search a Search Results page is displayed. D10359-1 4. Press ENTER to display the Transducer Setup start search page. 5. Press ENTER again, to initiate a system search for transducers.
81284_1.book Page 14 Friday, May 4, 2007 7:29 AM 14 ST70 Instrument User Reference Manual 12. Press to select the upper (offset type) adjust box. 13. Use < or > to scroll to either Water line, Keel or Transducer, as required. If you select Transducer, an offset value of zero is automatically applied. 14. If you have selected: • Either Water line or Keel, press to select the lower (offset value) adjust box then use < or > to set the correct value. • Transducer, ensure the offset value is zero. 15.
81284_1.book Page 15 Friday, May 4, 2007 7:29 AM Chapter 2: Commissioning Procedures 15 Set ground wind You can choose either Speed Over Ground (SOG) or Speed Through Water (STW) from which to derive the ground wind speed. To set the required method: Advanced Options 1. With the Advanced Options menu displayed, use < or > to select the Ground Wind option. Press ENTER to select Ground Wind SOG Select data source for Ground Wind. i Set magnetic variation Press ENTER to accept D10057-1 2.
81284_1.book Page 16 Friday, May 4, 2007 7:29 AM 16 ST70 Instrument User Reference Manual 4. Use < or > to select the required mode: • Select ON if you want to set a value for variation. if you choose this mode, the value you set will be applied to the rest of the system. • Select OFF if you do not want to apply a variation value to the system. • If SLAVE is displayed in the mode adjust box, the variation has been set at another product in the system, and the value is shown in the lower adjust box.
81284_1.book Page 17 Friday, May 4, 2007 7:29 AM 17 5. Press ENTER to display the response adjust box Speed for the data you have selected. 6. Use < or > to set the response rate. A higher 12 value gives a quicker response rate and vice versa. 7. Press ENTER to save the value and return to < & > adjust response level. the Response menu. i CANCEL exits without saving 8.
81284_1.book Page 18 Friday, May 4, 2007 7:29 AM 18 ST70 Instrument User Reference Manual To carry out any seatrial calibration procedure, switch on the instrument, then when an operational page is displayed: 1. Press MENU to select the Main Menu. Advanced Options 2. Use < or > to select Advanced Options. 3. Press ENTER to display the Advanced Options menu 4.
81284_1.book Page 19 Friday, May 4, 2007 7:29 AM Chapter 2: Commissioning Procedures 19 3. Use < or > to scroll to the Calibrate Vane option. Wind Press ENTER to select. 4. Press ENTER to select the Calibrate Vane start screen. 5. Keeping the boat speed below 2 knots and observing the screen, turn the boat in circles, then press ENTER to start the calibration. D10061-1 Calibrate Vane Raymarine i Serial no. 100030 Calibrate Vane Press ENTER to continue Calibrate Vane 35% i Keep turning....
81284_1.book Page 20 Friday, May 4, 2007 7:29 AM ST70 Instrument User Reference Manual If there is any inaccuracy after you have completed the Align Vane procedure, then: 1. At the Wind transducer setup menu, select Vane Vane Adjust Adjust, to display the Vane Adjust screen. 2. Sail the boat directly into the wind, then use < 15° and > to manually set the wind reading to zero. 3. Press ENTER to accept the value and return to the Wind transducer setup menu. Manually adjust your vane offset. i 4.
81284_1.book Page 21 Friday, May 4, 2007 7:29 AM Chapter 2: Commissioning Procedures 21 Start speed calibration To calibrate the Speed transducer: 1. With the Transducers Found menu displayed (see Preliminary procedures on page 18), use < or > to scroll to the Speed option. Transducers Found Press ENTER to select. 2. Press ENTER to select the Speed transducer setup menu. 3. Use < or > to scroll to the Calibration option. D10080-1 Speed Raymarine i Serial no.
81284_1.book Page 22 Friday, May 4, 2007 7:29 AM 22 ST70 Instrument User Reference Manual 6. Use < or > to select the next calibration speed. 7. Repeat Set to SOG steps 2 to 6, until calibration factor values have been set for all calibration speeds. 8. Press ENTER to save the values and return to the Speed transducer setup menu. 9. Press CANCEL to return to the Transducers found menu. Manual calibration D10323-1 To manually set the correct speed:. Calibration speed 1.
81284_1.book Page 23 Friday, May 4, 2007 7:29 AM Chapter 2: Commissioning Procedures 23 2.3 Return to normal operation When you have completed all the appropriate dockside setup and seatrial calibration procedures, return to normal operation as follows: 1. With the Transducers found menu displayed, press CANCEL to select the Search Results screen. 2. Press CANCEL to select the Transducer Setup screen showing the search initiation message. 3. Press CANCEL to select the Advanced options menu. 4.
81284_1.book Page 24 Friday, May 4, 2007 7:29 AM 24 ST70 Instrument User Reference Manual www.Busse-Yachtshop.de info@busse-yachtshop.
81284_1.book Page 25 Friday, May 4, 2007 7:29 AM 25 Chapter 3: Setup Procedures 3.1 Introduction Many operating parameters are set during commissioning and may not need to be changed again. However, if any of these parameters are not as you want them, you can change • The method of ground wind calculation. Refer to Chapter 2: Commissioning Procedures. • The magnetic variation. Refer to Chapter 2: Commissioning Procedures. • The response rate of an instrument. Refer to Chapter 2: Commissioning Procedures.
81284_1.book Page 26 Friday, May 4, 2007 7:29 AM 26 ST70 Instrument User Reference Manual Setting Vessel Type If you change the Vessel Type, you must then ensure all other parameters are set as you require before using the boat, as some other parameters change when the Vessel Type changes. 1. At the Advanced Options menu, use < and > to Vessel Type select Vessel Type, then press ENTER to display the Vessel Type menu. 2.
81284_1.book Page 27 Friday, May 4, 2007 7:29 AM Chapter 3: Setup Procedures 27 Setting time format Note: If you want to set the correct local time, refer to the Press ENTER to accept ST70 Instrument Operation Guide. D9779-1 1. At the Time & Date menu, use < or > to scroll to the Set time format option. 2. Press ENTER to display the Set time format box, Set time format then use < or > to select either 12 hour or 24 hour format, as required. 12-hour 3.
81284_1.book Page 28 Friday, May 4, 2007 7:29 AM 28 ST70 Instrument User Reference Manual www.Busse-Yachtshop.de info@busse-yachtshop.
81284_1.book Page 29 Friday, May 4, 2007 7:29 AM 29 Chapter 4: Maintenance & Troubleshooting 4.1 Maintenance Servicing and safety Unless specific instructions are given to the contrary, Raymarine equipment should be serviced only by authorized Raymarine service technicians. They will ensure that service procedures and replacement parts used will not affect performance. Some products generate high voltages, so never handle the cables/connectors when power is being supplied to the equipment.
81284_1.book Page 30 Friday, May 4, 2007 7:29 AM 30 ST70 Instrument User Reference Manual 4.2 Troubleshooting In the unlikely event that you encounter problems using your ST70 instrument, use this section to resolve the situation. First considerations If your ST70 is not performing as you think it should, be sure you are operating correctly as described in the ST70 Operating Guide, supplied with the instrument. Then: • Ensure that any data you think may be missing, is available on your boat.
81284_1.
81284_1.book Page 32 Friday, May 4, 2007 7:29 AM 32 ST70 Instrument User Reference Manual ST70 user troubleshooting Chart 2 Data missing Is the display lit? Refer to Chart 1 NO YES Are some data types present? NO YES Are the same data types missing from more than one product in the system? NO YES Ensure all system connections are satisfactory. Ensure connections to relevant transducer(s) and pod(s)are satisfactory.
81284_1.book Page 33 Friday, May 4, 2007 7:29 AM Chapter 4: Maintenance & Troubleshooting 33 ST70 user troubleshooting Garbled information on screen Chart 3 Are other instruments in system working OK? NO YES Ensure all system connections are satisfactory. Is problem still present? NO YES Obtain technical assistance Return to normal operation Using About Display feature The About Display function provides information about the instrument on which it is run.
81284_1.book Page 34 Friday, May 4, 2007 7:29 AM 34 ST70 Instrument User Reference Manual To run the About Display function: 1. With the instrument switched on, press MENU to display the Main Menu, then use < or > to select the Diagnostics option. 2. Press ENTER to display the Diagnostics menu. Main Menu Press ENTER to select. D10095-1 Diagnostics D10097-1 3. With the Diagnostics menu displayed, use < or About Display > to select the About display option, then press Software Ver. V0.20 Hardware Ver.
81284_1.book Page 35 Friday, May 4, 2007 7:29 AM Chapter 4: Maintenance & Troubleshooting 35 Telephone help line If you do not have access to the world wide web, please call the Raymarine help line.
81284_1.book Page 36 Friday, May 4, 2007 7:29 AM 36 ST70 Instrument User Reference Manual www.Busse-Yachtshop.de info@busse-yachtshop.
81284_1.book Page 37 Friday, May 4, 2007 7:29 AM 37 Specification Supply voltage: Nominal Maximum Minimum Absolute 12 V dc 16 V dc 9 V dc maximum: 18 V dc Current: Nominal Maximum dependent on screen brightness Not more than 220 mA Dimensions (excluding studs) 4.33 in W x 4.53 in H x 1.28 in D (110 mm x 115 mm x 32.5 mm) Connections Two SeaTalkng Operating temperature -20º to +70ºC Illumination Sliding scale Compliances RoHS EMC EN60945 Revision 4 Buzzer Monotone buzzer www.
81284_1.book Page 38 Friday, May 4, 2007 7:29 AM 38 ST70 Instrument User Reference Manual www.Busse-Yachtshop.de info@busse-yachtshop.
81284_1.
81284_1.book Page 40 Friday, May 4, 2007 7:29 AM 40 ST70 Instrument User Reference Manual www.Busse-Yachtshop.de info@busse-yachtshop.
81284_1.
81284_1.