Product specifications

Chapter 3: Installation
15
Clamp screws
Gasket
Adaptor
pieces
Grub screw
Rail diameter 23 mm (0.9 inch) or more but
less than 25 mm (1.0 inch), use adaptor pieces
Rail diameter 25 mm (1.0 inch),
do not use adaptor pieces
Clamping methods for
different rail sizes
D4834-1
Rail clamp details
Using the Rotavecta rail clamp
Running transducer cable
The Rotavecta transducer has a 20 m (65 ft) cable, fitted with spade
terminals at the free end, for connection to the ST40 Wind instrument.
Observing the following guidelines, run the cable to the instrument:
If the cable has to be fed through the deck, always use a good quality
deck gland.
Where cables are fed through holes, always use grommets to prevent
chafing.
Secure long cable runs so they do not present a hazard.
Wherever possible, route the cable away from fluorescent lights,
engines, radio transmitting equipment, as these may cause
interference.
160_3c03 .p65 01/05/01, 16:1515