Product specifications
3-8 hsb
2
PLUS Series Color LCD Display
Adjusting Gain, Sea
Clutter, Rain Clutter
and Tune
4. Use thetrackpad to move theslider up or down. You can press and holdthe
control to move the slider quickly rather than in single steps.
Theimageon thescreenchangesasyoumovetheslider, sothatyoucansee
the effect of your adjustment.
Ifyou selectMANUAL TUNE adjustment, an8-stepsignal-strength indicator
bar is displayed above the slider. Adjust the slider to obtain the maximum
reading on the indicator.
Note: Because the changes to the settings are made immediately, you cannot
revert to the previous setting by pressing CLEAR.
5. When you have set all the controls to the levels you require, press ENTER,
or CLEAR to clear the slider display. The status bar is updated to indicate
which controls are switched to Auto or On.
Gain Control and Sea Control
The GAIN control can be set to either Auto or Manual. In Auto mode, the
Pathfinder Plus radaroptimizesthe setting.The SEA controlcan be settoAuto-
Harbour (default), Auto-Offshore or Manual mode. In Auto-Offshore mode,
thePathfinderPlusRadaroptimizesitssettingstoaccountfortheeffectsof sea
clutter. In harbours or close proximityto land differentauto settings may
be necessary to cater for the effects of land clutter. To avoid losing small
targetsit is therefore advisable to set the Sea control to Auto-Harbour
mode. Alternatively, set both Sea and Gain to Manual mode then adjust
the settings to ensure that all close small targets are visible.
The GAIN control adjusts the level of the display of signals received from the
scanner; it is equivalent to a volume control on a radio.
Becausethe SEA control affects the gain,youmay need to manually readjustit
if you manually change the Gain setting.
Gain Control
When the GAIN control is set to Manual, you should check it every time you
change the range scale.
On long range settings, the gain should be set to give a slight speckle in the
background of the radar picture. Do not set the gain too low, or you may miss
small or weak targets.
On shorter ranges, you may wish to reduce the gain slightly to reduce the
speckle and therefore improve target definition.
MANUAL
GAIN
50%