Product specifications
Chapter 6: Further Chart Operations 6-5
Setting Alarms and
Timers
Setting Alarms and Timers
➤ Tosetupanalarmortimer:
1. Press the ALARMS key. The Alarms Set Up menu is displayed, showing
the current settings (see Figure 6-2).
2. Use thetrackpadtomove the selectionbar up ordown theoptions.Aseach
line is highlighted, the soft key labels are updated to show the current set-
tings and controls.
Figure 6-2: Alarms Set Up List
3. Use the up or down soft keys to change the alarm setting. For example, for
the arrival alarm you can adjust the radius from the waypoint at which the
arrival alarm will be triggered.
The arrival, off track and anchor alarm distances can be set in the range
0.01 to 9.99 nm, in steps of 0.01nm.
Thegrounding alarmdepth canbe setfrom 1to20m in 1msteps andcan be
specified to cover a sector at a range from 0 to 1nm, in 0.1nm steps.
Thetimer issetin hours,minutes and seconds,and the alarmclockinhours
and minutes.
4. If required, press the ALARM OFF ON soft key to toggle the alarm on or off.
Ifyou turn analarm off,its valueisretainedand willbeused when youturn
the alarm on again.
Note:You can turn all the alarms and timers on and off, except for the Arrival
Alarm which is always on.
5. Press ENTER to save the changes and clear the list.
ALARMS
SELECT ARRIVAL
ALARM RADIUS
ALARMS SET UP
OFF TRACK ALARM
ANCHOR ALARM
COUNTDOWN TIMER
ALARM CLOCK
ON
OFF
00:33:00
OFF
ARRIVAL ALARM
0.01nm
D4265-4
GROUNDING ALARM
5M/1.0nm
ALARM
OFF ON