User`s manual
Interfacing RNS 35
Connecting to Ockam Instruments
RNS connects to Ockam instruments via the Ockam Model 050D RS-232 Interface (not
supplied). You must also set two switches on the Ockam unit.
You can connect RNS using any Ockam RS-232 interface, however for optimum
reliability of data transfer the Model 050D is recommended.
To connect to a Model 050D RS-232 interface:
1. On the interface, set switch
S1
to 4.
2. Set switch
S2
to D.
Connecting a USB C-Card Reader
This section describes connecting a USB C-Card reader to your PC system.
To install a USB C-Card reader to your PC:
1. Plug your C-Map USB C-Card reader into your computer.
2. Click
Start
on the computer taskbar. The pop-up menu is displayed.
3. Click
Control Panel
. The control panel is displayed.
4. Click
Add/Remove Hardware
. The Add/Remove Hardware wizard is displayed.
5. Click Next. Follow the on-screen instructions.
3. Connect the cables as follows:
Cable color Ockam 050D pin
Yellow (Rx) Pin 4
Black (SGnd) Not used
Green (Tx) Pin 2
Black (SGnd) Pin1
D6979_1