Installation manual
G-Series Installation & Commissioning 98
Fishfinder
9.2 Status LEDs
SeaTalk
hs
Switch LED indications
• Problem • Possible cause / solution • Possible solutions
• No data source for the fishfinder. • DSM power supply fault. • Check the DMS power supply.
Refer to troubleshooting Power up on page 92.
• Other DSM fault. • Refer to the instructions supplied with the DSM unit.
• SeaTalk
hs
network problem. • Check that the DSM is correctly connected to the
SeaTalk
hs
switch.
• Check the status of the SeaTalk
hs
Switch.
Refer to troubleshooting Status LEDs on page 98.
• Check that SeaTalk
hs
cables are free from damage.
• Software mismatch between equipment may
prevent communication.
• Contact Raymarine technical support
• Invalid custom configuration message • Indicates an invalid manual override of switch
settings at the transducer
• Refer to your DSM and Transducer documentation for
further information
LED State (Connected channels only) Causes
• For all connected channels:
1 steady and 1 flashing green LED.
• No problem detected
(Steady LED indicates network connection
Flashing LED indicates network traffic)
• No LEDs are illuminated • No power to SeaTalk
hs
switch
• Some LEDs are not illuminated • Cable / connection faults on the channels with non-illuminated LEDs.
• Equipment connected to non-illuminated LEDs may be faulty.