97 Chapter 9: Troubleshooting
Data
Problem Possible cause / solution Possible solutions
Instrument or other system data is unavailable
at all Nav Stations.
Data not received at Master GPM. Check the data bus (e.g. SeaTalk
ng
) wiring and connec-
tion to the master GPM.
Check the overall integrity of the data bus (e.g.
SeaTalk
ng
) wiring.
If available refer to the reference guide for the data bus.
(e.g. SeaTalk
ng
reference manual)
Data source (e.g ST70 instrument) is not
operating.
Check the source of the missing data (e.g. ST70
instrument)
Refer to the manufacturers handbook for the equipment in
question.
Software mismatch between equipment may
prevent communication.
Contact Raymarine technical support
Instrument or other system data is missing from
some but not all Nav Stations.
SeaTalk
hs
network problem Check that all GPM400s are connected to the SeaTalk
hs
switch.
Check the status of the SeaTalk
hs
Switch.
Refer to troubleshooting Status LEDs on page 98.
Check that SeaTalk
hs
cables are free from damage.
Software mismatch between equipment may
prevent communication.
Contact Raymarine technical support