Installation manual
G-Series Installation & Commissioning 94
Radar
• Keypresses result in improper or no action at
the display.
• Software mismatch between equipment may
prevent communication.
• Contact Raymarine technical support
• Keyboard does not control the expected monitor
or Nav Station.
• Keyboard is not assigned to the correct Nav
Station(s).
• Assign keyboard to Nav station (see Assign Keyboards
on page 78).
• Incorrect monitor is selected at Keyboard • Check the Keyboard LCD to see which monitor is
currently being used. Use the left/right arrow keys to
select between the available monitors.
• Keyboard does not operate monitor setting
menus.
• Refer to troubleshooting Marine Monitors on page 92
Problem Possible causes Possible solutions
Problem Possible causes Possible solutions
• No Data or No scanner message. • Radar scanner power supply • Check that the scanner power supply cable is sound and
that all connections are tight and free from corrosion.
• Check relevant fuses and breakers.
• Check power source is of the correct voltage and suffi-
cient current (using voltage booster if appropriate).
• SeaTalk
hs
network problem • Check that all radar scanners are correctly connected to
the SeaTalk
hs
switch.
• Check the status of the SeaTalk
hs
Switch.
Refer to troubleshooting Status LEDs on page 98.
• Check that SeaTalk
hs
cables are free from damage.
• Radar scanner fault • Refer to the radar scanner handbook.
• Software mismatch between equipment may
prevent communication.
• Contact Raymarine technical support