Installation manual

G-Series Installation & Commissioning 94
Radar
Keypresses result in improper or no action at
the display.
Software mismatch between equipment may
prevent communication.
Contact Raymarine technical support
Keyboard does not control the expected monitor
or Nav Station.
Keyboard is not assigned to the correct Nav
Station(s).
Assign keyboard to Nav station (see Assign Keyboards
on page 78).
Incorrect monitor is selected at Keyboard Check the Keyboard LCD to see which monitor is
currently being used. Use the left/right arrow keys to
select between the available monitors.
Keyboard does not operate monitor setting
menus.
Refer to troubleshooting Marine Monitors on page 92
Problem Possible causes Possible solutions
Problem Possible causes Possible solutions
No Data or No scanner message. Radar scanner power supply Check that the scanner power supply cable is sound and
that all connections are tight and free from corrosion.
Check relevant fuses and breakers.
Check power source is of the correct voltage and suffi-
cient current (using voltage booster if appropriate).
SeaTalk
hs
network problem Check that all radar scanners are correctly connected to
the SeaTalk
hs
switch.
Check the status of the SeaTalk
hs
Switch.
Refer to troubleshooting Status LEDs on page 98.
Check that SeaTalk
hs
cables are free from damage.
Radar scanner fault Refer to the radar scanner handbook.
Software mismatch between equipment may
prevent communication.