Installation Instructions

6.5LEDindications
ThepowerLEDforthisproducthasanumberofashing(blinking)modestoprovidestatusinformationfordiagnosticsand
troubleshooting.
LEDcolorLEDcodeStatusUseraction
SolidGreenPowerOnNone(normalpoweruptakes<1minute.)
Green1blink
NormaloperationNone
Amber1
blink
Transducer
disconnected
Ensuretransducercableandconnectionsaresecureand
freefromdamage.
Powercycleunittorecovertransducerinformation.
IfproblempersistscontactRaymarinetechnicalsupport.
Amber2
blinks
Nonetwork
detected
Ensurenetworkispowered.
Ensurenetworkcableandconnectionsaresecureandfree
fromdamage.
IfproblempersistscontactRaymarinetechnicalsupport.
Amber5
blinks
Undervoltage
(<10.2V)
Ensurepowercableandconnectionsaresecureandfree
fromdamage.
Ensurepowersupplycablingisconsistentwith
recommendations.
IfproblempersistscontactRaymarinetechnicalsupport.
Amber6
blinks
Overvoltage
(>34.2V)
Ensurepowersupplylevelsareconsistentwith
recommendations.
IfproblempersistscontactRaymarinetechnicalsupport.
Red1blink
GeneralfailureIfcombinedwithvoltagewarning,checkpowersupplyand
cables.
Power-cycletheunit.
IfproblempersistscontactRaymarinetechnicalsupport.
Red3blinksUnitoverheatingEnsureinstallationenvironmentiswithinrecommendations.
Unitwillstoppingingandthenstartagainoncenormal
operatingtemperatureisachieved.
IfproblempersistscontactRaymarinetechnicalsupport.
Red4blinksProblemswith
internaldatabase
Power-cycletheunit.
IfproblempersistscontactRaymarinetechnicalsupport.
Note:IfanyotherLEDsequenceotherthandescribedaboveisseenandpersistspleasecontactRaymarinetechnicalsupport.
Systemchecksandtroubleshooting
33