Installation Instructions
6.5LEDindications
ThepowerLEDforthisproducthasanumberofashing(blinking)modestoprovidestatusinformationfordiagnosticsand
troubleshooting.
LEDcolorLEDcodeStatusUseraction
SolidGreenPowerOn•None(normalpoweruptakes<1minute.)
Green1blink
Normaloperation•None
Amber1
blink
Transducer
disconnected
•Ensuretransducercableandconnectionsaresecureand
freefromdamage.
•Powercycleunittorecovertransducerinformation.
•IfproblempersistscontactRaymarinetechnicalsupport.
Amber2
blinks
Nonetwork
detected
•Ensurenetworkispowered.
•Ensurenetworkcableandconnectionsaresecureandfree
fromdamage.
•IfproblempersistscontactRaymarinetechnicalsupport.
Amber5
blinks
Undervoltage
(<10.2V)
•Ensurepowercableandconnectionsaresecureandfree
fromdamage.
•Ensurepowersupplycablingisconsistentwith
recommendations.
•IfproblempersistscontactRaymarinetechnicalsupport.
Amber6
blinks
Overvoltage
(>34.2V)
•Ensurepowersupplylevelsareconsistentwith
recommendations.
•IfproblempersistscontactRaymarinetechnicalsupport.
Red1blink
Generalfailure•Ifcombinedwithvoltagewarning,checkpowersupplyand
cables.
•Power-cycletheunit.
•IfproblempersistscontactRaymarinetechnicalsupport.
Red3blinksUnitoverheating•Ensureinstallationenvironmentiswithinrecommendations.
•Unitwillstoppingingandthenstartagainoncenormal
operatingtemperatureisachieved.
•IfproblempersistscontactRaymarinetechnicalsupport.
Red4blinksProblemswith
internaldatabase
•Power-cycletheunit.
•IfproblempersistscontactRaymarinetechnicalsupport.
Note:IfanyotherLEDsequenceotherthandescribedaboveisseenandpersistspleasecontactRaymarinetechnicalsupport.
Systemchecksandtroubleshooting
33