Reference Manual Part 2

145 Chapter 11: Radar
‘Sync’ is displayed in the top left-hand corner of the chart
window.
If you change the radar range, all synchronized chart views
change scale to match.
If you change the scale of a synchronized chart window, all ra-
dar windows update to match.
To synchronize radar range and chart scale
1. Make a chart window active.
2. Press the PRESENTATION softkey.
3. Press CHART MODE AND ORIENTATION.
4. Toggle to RDR on the CHART SYNC softkey.
Note: Radar range synchronization is not available when the chart
motion mode is set to autorange, nor when the selected
scanner is set to dual range.
11.10 Measuring distance, range and
bearing
You can measure distance, range and bearing in the radar applica-
tion. Options for doing so are detailed in the table below.
Range rings
Range rings help you gauge the approximate distance between
points at-a-glance. Range rings are centred on your position and
displayed on the screen at pre-set intervals.
The number and spacing of range rings changes to suit the scale
you have set.
To show or hide range rings
1. Press the PRESENTATION softkey.
2. Toggle to ON or OFF using the RANGE RINGS softkey.
Bearing and range
The radar display shows you bearing and range data to any object
you highlight.
To find the bearing and range to an object
1. Move the cursor to the object’s position.
2. Read off the bearing and range in the databar.
Functions
Distances
between
points
Range from
your boat
Bearings
Range Rings Yes (approx.) Yes (approx.) -
Cursor - Yes Yes
Variable Range
Markers (VRMs)
- Yes -
Electronic Bearing
Lines (EBLs)
- - Yes
Floating VRMs Yes - -
Floating EBLs - - Yes
Functions
Distances
between
points
Range from
your boat
Bearings
Range -
1
/
4
nm
Range rings -
1
/
8
nm apart
Range -
3
/
4
nm
Range rings -
1
/
4
nm apart
Range - 1
1
/
2
nm
Range rings -
1
/
4
nm apart
D8407_1
e.g.