Specifications
SEE FIG. 7
CHANGE THE NOZZLE AT THE ANNUAL SERVICE.
1. Remove blast tube by slackening two hex. screws.
Thoroughly clean the blast tube.
2. Remove (2) screws securing access door.
3. Slacken (2) screws on either side of access door.
4. Open access door.
5. Remove push on electrode leads.
6. Slacken screws securing electrodes.
7. Pull out electrodes.
8. Using socket spanner unscrew nozzle. Ensuring
hexagon is held, to stop nozzle holder turning.
9. Remove nozzle and check filter for debris. Replace
with one of same specified make and pattern
10. Refit nozzle taking care not to overtighten.
11. Re-assemble in reverse order.
NOTE: Do not touch the face of nozzle to avoid blocking
of fine drilling.
SEE FIG. 7 and PAGE 15.
Inspect the ignition electrodes for crazing in the porcelain.
Replace if there are any signs of deterioration.
8
Oil Burner Servicing
BURNER NOZZLE REMOVAL
IGNITION ELECTRODE
FIG. 7 DESN 510238
DESN 511437
DESN 511436 A
SLACKEN (2) HEX.
SCREWS