Specifications
IMPORTANT NOTE: This appliance is fitted with an
overheat thermostat which has a manual reset button.
If the overheat stat trips, the cooker will not operate,
until the button has been pushed-in (reset). The
engineer needs to follow ‘Fault Finding Guide’ to
establish why the stat tripped. (The overheat
thermostat and its sensing phial are located on the
controls chassis rear). (See Fig. 25).
This thermostat is a safety cut-out device which will
operate under adverse wind or a blocked flue condition. It
is a manually reset device which can be reset by pressing
in the centre.
SEE FIG. 18
1. Remove plinth (3 screws).
2. Unscrew two fixing screws just in front of PCB.
3. Lift the PCB slightly and slide forward.
SEE FIG. 19
1. Check the control voltage to the fan.
2. Turn the appliance on. Between + and - the voltage
will be 24V dc.
3. Between - and signal the voltage should read
approximately 4.0V dc initially, then drop to 2.6V dc
after 30 seconds.
4. The fan should also slow down.
Electrical Controls
OVERHEAT SAFETY THERMOSTAT
FLUE SAFETY DEVICE
REMOVAL OF PCB
POWER FLUE CONTROL
DESN 514123 BFIG. 17
FIG. 18
FIG. 19 DESN 512562
14
DESN 512570