Specifications

The installation of the appliance must be in accordance
with the relevant requirements of the current Building
Regulations, current I.E.E. Wiring Regulations and the
byelaws of the local Water Authority.
It should be in accordance also with any relevant
requirements of the Local Authority and the relevant
recommendations of the following current British Codes
of Practice:
BS.5410 Installation of oil fired space heating and hot
water supply purposes. Boilers of rated output not
exceeding 44kW.
Building Regulations
J/1/2/3 Provision for introduction of air supply and
discharge of products of combustion for
appliances.
BS.4543 Specification for chimney for oil fired
appliances. Part 3.
Building Regulations
J/1/2/3 Provision for protection against fire and
heat.
Appliance Hearth
This appliance must be installed on a solid level floor or
base of incombustible material which is a capable of
supporting the total weight.
The location chosen for the appliance must permit
installation and the provision of a satisfactory flue and
an adequate air supply. The location must also provide
adequate space for servicing and air circulation around
the appliance. See "Installation of Appliance".
Where the cooker is to stand in a recess or against
a wall, in no circumstances should the tiles overlap
the cooker top plate.
The minimum recommended oil tank size is 1400 litres
(300 gallons) and the Codes of Practice governing its
installation are covered by BS.5410.
The requirements for mild steel tanks should be to BS.799
Part 5. Plastic Oil Tanks to OFTEC Standard OFS T100.
The oil storage tank must be positioned with the bottom of
the tank not less than 630mm, and the top not more than
3.2m above the base of the cooker.
Oil Pipe Line
The oil line from the storage tank to the appliance must be
fitted with a remote acting fire valve (such as a Teddington
KBB-66°C) located outside the building, or where the
supply enters the wall on the inside of the building and with
the heat sensing phial of the fire valve, located as near as
practicable on the L.H. side of the cooker.
A 5-10 micron oil filter should also be fitted in the oil line,
and the minimum size of the copper oil pipe line should not
be less than 10mm diameter.
A stop valve must be fitted near the appliance, in an
accessible position.
We also recommend an additional remote acting fire valve
be fitted close to the oil control valve, with its heat sensing
phial located in the burner housing, but not touching, the
inner burner door.
Installation Instructions
LOCATION
OIL STORAGE - See fig.1
2
Fig.1 Oil Storage tank and pipeline
details
DESN 510210
PLEASE NOTE: IT IS ADVISABLE TO CHECK
THE WIDTH OF YOUR APPLIANCE BEFORE
FINALLY FIXING ANY KITCHEN UNITS
SINCE ENAMELLED CAST IRON CAN VARY
IN SIZE
DESN 511031
DIMENSIONS IN MILLIMETRES
840
100
100
65
590
1245
820
165
260
543
90
995
320
305
848
60
100
INSTALLATION INSTRUCTIONS