Specifications
The thermostat will close down when the water
reaches the temperature chosen by the selected set-
ting, it will close fully when the water temperature
reaches 90 - 95
o
C when set at 5 - to prevent boiling.
(See Fig. 5)
The thermostat manual override has 4 settings which
retain the air flap in a predetermined open position for
steady heat when baking and cooking. It will only
close fully when the water temperature reaches 90 -
95
o
C when set at 5 - to prevent boiling.
6
There is a small air bypass into the ashdoor and this
is normally sufficient when the thermostat is closed to
hold the fire at least 10 hours after banking. If the fire
is out and the fuel unburned set the control knob of
the thermostat from
1
/2 to 1 in order to sustain
overnight burning.
OVERNIGHT BURNING
FIREDOOR SPIN VALVE
Heated secondary air enters the firebox through a
spin valve in the firedoor back plate while the valve is
open to assist combustion of smoke volatiles.
Close when burning anthracite. (See Fig.6)
The ashdoor spin valve allows additional air to the
firebox for marginal draught conditions. This can be
adjusted to suit your requirements. Close when set-
ting the cooker for overnight burning. (See Fig.7)
This plate is fitted by removing the hotplate and slid-
ing the insulating plate down between the boiler and
oven side. Make sure that the spacing projections are
facing the oven and the top flange is resting on the
boiler. Replace the hotplate.
The boiler insulating plate may be used with the sum-
mer plates or on its own as a means of reducing the
boiler output and increasing the heat to the oven.
(See Fig. 8)
ASHDOOR SPIN VALVE
BOILER INSULATING PLATE
Fig.5
Fig.6
Fig.8
Spin Valve
Fig.7