Operating instructions
Preliminary Installation
The appliance is delivered assembled with the exception
of the following items which are supplied separately
packed and require assembly.
1. Draught Diverter Assembly
See Fig. 4.
2. Appliance Rear Distance Bracket (For use when
appliance is Bracket installed 25mm away from a
rear wall of combustible material). See Fig. 5.
3. Insulating Covers.
4. Handrail Brackets and Handrail
Site Location
1. Remove the appliance assembly from its transit
wooden pallet by the temporary location of a
sloping ramp board between the pallet and the floor.
With the appliance on the floor carefully lift the appliance
(taking care not to damage the enamelled/painted
components of the floor covering in the room) and insert
suitable rollers beneath the base plate to aid positioning
of the appliance.
When in position remove rollers and continue assembly.
NOTE: IF THE REAR WALL IS OF COMBUSTIBLE
MATERIAL, THERE MUST BE AN AIR GAP OF 25mm,
BETWEEN THE WALL AND REAR OF APPLIANCE.
FIT REAR DISTANCE BRACKET AS SHOWN IN FIG. 5.
2. Assemble and locate the flue draught diverter
assembly on the top plate. See Fig. 4.
3. Fit a 600mm minimum vertical height of flue pipe
into the draught diverter flue socket, sealing joint
with fire cement. See Fig. 6.
4. The flexible liner joint and the entire flexible liner
should be in the confines of the flue.
5. Insulating covers are placed in position and
secured in position (see instruction sheet provided)
4
Fig. 4
Fig. 5
Fig. 6