Specifications
Version C15. February 2013 Raveon Technologies Corporation
Company Confidential
19
3. ATCT setting set to 60000 (60 second time-out)
4. Encryption KEYPHRASE is erased (if it was set to some KEYPHRASE and the user-
interface had password protection enabled)
Even though the serial baud rate reverts to 9600 baud when the CONFIG button is
pressed and the IO port is RS232, it will revert back to the settings programmed
into the RV-M7 GX once the Command Mode is exited.
Important Note! If the user-interface is password protected, AND the Config
button on the M7 is pressed, for security reasons, the encryption phrase is
automatically erased.
5.7. Exiting the Command Mode
There are three ways to exit the command mode. They are:
1. ATCN Issuing the ATCN. The M7 radio will exit the command mode, and
begin normal operation.
2. EXIT Issuing the EXIT command. The M7 radio will exit the command mode,
and begin normal operation.
3. Time Out. After a pre-set amount of time (60 seconds is the factory default
time), the modem will automatically exit the Command Mode, and continue normal
operation. Changes will not automatically be saved. This time-out duration may be
set with the ATCT command.
5.8. Restoring Factory Defaults
The AT&F command may be used to restore the modem back to the factory-
default condition. The table in Section 5.9 lists all of the radio modem related
commands. Use this command with caution, as it will erase all previously
configured parameters. It will cause the modem to revert back to the factory-
defaults, as shown in the command table, “Factory Default” column. The only
parameters that it does not restore to default are the radio calibration values R0-
R9, and RA.
The GPS&F command resets only the GPS related settings back to factory
defaults. The modem itself keeps its settings. The GPS commands that are reset
are shown in Section 5.10.