User Manual

Company Confidential
20
Raveon Technologies Corp.
SL
Serial Number – Reads and returns a unique module
serial number.
Read Only
1 - 65525
unique
SH
Show – Display the configuration of the modem. This
will return a page of ASCII characters, showing the
main configuration parameters.
none
None
SV
Save – Save all the parameters to EEPROM. This
command must be used if changed parameters are to
be stored in non-volatile memory, and used next time
the modem is powered up. Modem exits configuration
mode after this command is executed.
none
None
TD
Transmit Random Data When issued, the modem
will begin sending random data. Entering a <CR> will
terminate the transmission.
0 = Go back to normal
1 = Random
2 = Hop up/dn one channel
3 = Force PLL to fast
4 = TX all 0s
5 = TX all 1s
6 = Test Points ON
7 = Transmit CW
8 = Transmit 1010101…
TM
Serial Port time out Number of uS of no activity
before transmitting.
Range: 0 - 5000000
20000
TT
Max Packet Size – Set the maximum number of bytes
in an over-the-air packet.
1 - 512
240
VR
Firmware Version – Returns firmware version
currently loaded on the module.
Read Only, 3
characters
none
&F
Restore Factory – Restore the factory default values.
This command will not erase the calibration values in
the flash unless the parameter is the three-digit string
“123”. After this command executes, the modem will
still be in the CONFIG mode.
None to maintain
calibration, “123” to
erase everything.
none
** indicates values that are calibrated in the factory and are unit-specific. If the
“Radio Type” is changed, these will need to be re-calibrated.
Default Frequencies
Channel 1 464.500000