User's Manual
Company Confidential 60 Raveon Technologies Corp.
F
igure 1 (Packet Mode of Operation)
For operation of the modem in the streaming data, non-packetized mode, see the
section Streaming Mode on page 37. The Packet or Streaming operation is
configured using the ATMT command, with Packet Mode being the factory
default.
6.1. Setup
1. Connect a DC power source to the DC IN connection on the front of the
modem.
2. Connect a good quality antenna, cut to the operating frequency, to the BNC
connector on the front of the modem. Use a good antenna, and place is at
high-above obstructions as possible.
3. Connect a computer terminal, or PC computer running HyperTerminal, to the
9-pin I/O connector. The factory default serial ports settings are 9600 bps, 8
data bits, 1 stop, no parity.
4. Program the modem’s operating frequency to your desired operating
frequency. This is done with the ATFX xxx.xxxxx command. See the section
“Serial Port Commands” for information describing the various parameters
that may be modified in the modem. In most applications, the default settings
from the factory will work fine.
5. Using the AT commands, change any of the default operating parameters that
must be modified. From the factory, the modems are configured and shipped
ready-to-use. Out of the box, they will communicate on the default radio
channel using the factory defaults. In general, the parameters you may want
to modify will be: