User`s manual

3-3
3
Installation and wiring
3. Installation and wiring
(6) Installation method and direction precautions
Install the robot driver on a vertical surface capable of supporting the weight. Secure
the robot driver firmly by screws or bolts.
If the robot driver is not installed vertically on the wall surface, the cooling capacity
may degrade causing a trip or alarm and/or damaging the internal components.
For mounting hole locations, refer to 8.2, "Robot driver dimensions and mounting
holes".
(7) Precautions when housing robot drivers in a box
When housing multiple robot drivers in a box and using ventilation fans, attach the
fans as shown below in order to ensure a uniform temperature around each robot
driver.
100mm or more
100mm or more
40mm or
more
40mm or
more
10mm or
more
10mm or
more
10mm or
more
Fan Fan
Wiring space of
75mm or more
Robot
driver
Install the robot drivers 40mm or more away from the inner side walls of the box and
100mm or more away from the inner top/bottom walls of the box. Allow a clearance
of 10mm or more between adjacent robot drivers.