User`s manual

6-13
6
Parameter description
6. Parameter description
Monitor
No.
Monitor name Display range Description
d-07
Position
command
monitor
80000000 (negative maximum)
to
7FFFFFFF (positive maximum)
[pulses]
Displays the position command in
a hexadecimal 32-bit signed (two's
complement) value. Displays the 5 low-order
digits immediately after d-07 is opened.
The display shifts to high-order digits by
pressing
to allow checking high-order
digits.
(A decimal point is placed between high-
order word and low-order word.)
d-08
Present position
monitor
80000000 (negative maximum)
to
7FFFFFFF (positive maximum)
[pulses]
Displays the position command in
a hexadecimal 32-bit signed (two's
complement) value. Displays the 5 low-order
digits immediately after d-08 is opened.
The display shifts to high-order digits by
pressing
to allow checking high-order
digits.
(A decimal point is placed between high-
order word and low-order word.)
d-09
Position error
monitor
80000000 (negative maximum)
to
7FFFFFFF (positive maximum)
[pulses]
Displays the position command in
a hexadecimal 32-bit signed (two's
complement) value. Displays the 5 low-order
digits immediately after d-09 is opened.
The display shifts to high-order digits by
pressing
to allow checking high-order
digits.
(A decimal point is placed between high-
order word and low-order word.)
d-10
Output voltage
monitor
0 to 400 [V] Displays the output voltage in 1V units.
d-11 Trip monitor
Displays the last alarm, speed command value, speed detection value,
current value, and DC bus voltage. Data is displayed in the following
sequence each time
is pressed.
Alarm number : E01-1, etc. (Last digit of -1 indicates the latest
information.)
Speed command value : −5000 (Contains no period.)
Speed detection value : −5000. (Contains a period.)
Current value : 4.60A
DC bus voltage : 270u
Input terminal information : Complies with d-05 display.
Output terminal information : Complies with d-06 display.
d-12 Trip log monitor
Refer to the example shown
on the right.
Displays the past 3 alarm logs except the
latest log. Pressing
or displays the
alarm number only. Pressing
displays
the alarm information.
Alarm number : E01-2, etc. (The larger
the last digit, the older
the log.)
Speed command :
−5000 (Contains no period.)
value
Speed detection :
−5000. (Contains a period.)
value
Current value : 4.60A
DC bus voltage : 270u
Input terminal :
Complies with d-05 display.
information
Output terminal :
Complies with d-06 display.
information