User`s manual

Parameter description
6
6-12
6. Parameter description
6.3 Function description
6.3.1 Monitor display description
To automatically display a parameter setting when power is on, display the monitor for
that parameter and press the
SET
key. This allows setting that parameter to appear when
power is turned on next time. This setting is cancelled when you clear the alarm log.
Monitor
No.
Monitor name Display range Description
d-00
Speed command
monitor
–7000 to 7000
RDX [min
-1
]
RDP [mm/s]
Displays the signed speed command value
in 1 min
-1
units.
d-01
Speed detection
value monitor
–7000 to 7000
RDX [min
-1
]
RDP [mm/s]
Displays the signed speed detection value
in 1 min
-1
units.
d-02
Output current
monitor
0 to 400 [%] Displays the output current in 1% units.
d-03
Torque command
monitor
–400 to 400 [%] Displays the torque command in 1% units.
d-04
Output torque
monitor
–400 to 400 [%] Displays the output torque in 1% units.
d-05
Input terminal
monitor
Displays the input terminal status. (See below.)
In this example, SON, FOT, ROT and PEN are ON and the others are OFF.
RS
ORL
SON
ON
OFF
TL
ORG
ROT
PEN
FOT
CER
Black: ON
White: OFF
d-06
Output terminal
monitor
Displays the output terminal status. (See below.)
In this example, OL1 and TLM are OFF, and the others are ON.
ALM
SRD
ON
OFF
INP
BRK
Black: ON
White: OFF