User`s manual
Parameter description
6
6-10
6. Parameter description
(3) Input/output terminal parameters
Parameter
No.
Parameter name Setting range
Default setting Units
Change
during
operation
RDX RDP RDX RDP
FC-01
Input terminal
polarity setting
0000 to 3FFF 0400 – No
FC-02
Output terminal
polarity setting
0000 to 00FF 0002 – No
FC-09
Position sensor
monitor resolution M
16 to 8192 1 – No
FC-10
Position sensor
monitor resolution N
1 to 8192 4 1 – No
FC-11
(Note 1)
Position sensor
monitor polarity
A, b b – No
FC-12
(Note 1)
Phase Z output
selection
1PLS, nCunt
ECunt, qFort
1PLS – No
FC-19
Command pulse
filter time constant
Lo, Hi Hi – No
FC-21
Communication
baud rate
1200, 2400,
4800, 9600,
19200, 38400
19200 bps No
FC-22
Communication bit
length
7, 8 8 bit No
FC-23
Communication
parity
non, odd, EvEn non – No
FC-24
Communication
stop bit
1, 2 2 – No
FC-30
Monitor output 1
function
nrF, nFb, iFb,
tqr, nEr, PEr,
PFq, brd
nFb – No
FC-31
Monitor output 1
polarity
SiGn, AbS SiGn – No
FC-32
Monitor output 1
gain
0.0 to 3000.0 100.0 % No
FC-33
Monitor output 2
function
nrF, nFb, iFb,
tqr, nEr, PEr,
PFq, brd
tqr – No
FC-34
Monitor output 2
polarity
SiGn, AbS SiGn – No
FC-35
Monitor output 2
gain
0.0 to 3000.0 100.0 % No
FC-40
Input terminal
function
0 to 3FFF 0 – No
FC-70
(Note 1)
Debug mode
selection
00––
Note 1: Do not change the setting.