User`s manual
6-7
6
Parameter description
6. Parameter description
6.2.2 List of setup parameters
Parameter setting ranges and default values are shown in the following tables.
(1) Operation mode parameters
Parameter
No.
Parameter
name
Setting range
Default setting Units
Change
during
operation
RDX RDP RDX RDP
FA-00
(Note 3)
Control mode
S-P, S-t, P-t,
P-S, t-S, t-P
P-S – No
FA-01
Position sensor
wire breaking
detection
OFF, on on – No
FA-02
Allowable time of
power failure
0.00, 0.05 to
1.00
0.00 s No
FA-03
Overspeed error
detection level
0 to 150 110 % No
FA-04
Speed error
detection value
0 to maximum
speed
Depends on model min
-1
mm/s No
FA-05
Position error
detection value
0.0 to 100.0 20.0 rotation No
FA-07
(Note 3)
DC bus power
supply
L123, Pn L123 – No
FA-08
Regenerative
braking
operating ratio
0.0 to 100.0 Depends on model % No
FA-09
Overload notice
level
20 to 100 80 % No
FA-10
Auto tuning
mode
non, oFL,
FFt
non – No
onL1
, onL2
(Note 3)
FA-11
Pulse train input
mode
F-r, P-S, A-b
r-F, -P-S, b-A
F-r – No
FA-12
Electronic gear
numerator
1 to 65535
Depends
on model
1
–No
FA-13
Electronic gear
denominator
1 to 65535 – No
FA-14
Motor revolution
direction
CC, C Depends on model – No
FA-16
DB Operation
selection
non, trP, SoF SoF – No
FA-17
(Note 3)
Torque limit
mode
non, A2, oP non – No
FA-18
Torque bias
mode
non, CnS
non – No
A2, oP
(Note 3)
FA-20
(Note 3)
Speed limit
mode
non, A1, oP non – No
FA-22
(Note 3)
Position
command
selection
PLS, Pro, oP PLS – No
Note 1: Displayed on RDP only.
Note 2: Invalid on RDP.
Note 3: Do not change the setting.
Note 4: Set this parameter to the default value for each model.