User`s manual

3-39
3
Operating Procedures
3. Operating Procedures
(2) Detailed setting
Clicking the [Options] button opens the following dialog box. Make settings as
needed. (You do not have to make these settings under normal conditions.)
(E)
(F)
(G)
(E) Number (number of data points)
Set the number of FFT computation points for mechanical system diagnosis.
The larger the number of points, the higher the measurement accuracy, but the
longer the time needed uploading data. Using a small number of points for initial
rough measurements and then increasing the number of points for final detailed
measurements will reduce the measurement time. Basically make measurements
using the maximum number of data points (4096).
(F) Window ( windowing function)
A windowing function is applied to the data. If it is difficult to see the measured
waveform, changing this setting may make it easier to see. You can select from
among "Hanning", "Hamming" or "Nothing". Basically make measurements using
"Hanning".
(G) Operation ( operation adjustment range)
Reducing this setting narrows the operation range during measurement. But this
makes it difficult to see the waveform in a low frequency region. If difficult to see
the waveform in a low frequency region in the default setting, then change it to a
larger value. Units for this parameter are as follows:
Rotary motor: rotations (number of revolutions)
Linear motor: magnetic pole pitch (mechanical length equal to 360° electrical
angle)