CHAPTER 3 Operating Procedures
3 - 43
3.5.4 Notch filter setup procedure
The notch filter parameter can be set by performing the procedure described below (it is
necessary to measure the resonance point as directed in the preceding section):
1- As shown below, left-click the mouse on a resonance point (a peak similar to the
pointed summit of a mountain) within the waveform display area of the mechanical
diagnostics window. If any fine adjustments are needed, use the cursor buttons on
the left-hand side until the mouse cursor is positioned at the peak.
2- Right-click the mouse at the intersection of a perpendicular line drawn from the
peak and the waveform line sloped downward to the right.
Left-click the
mouse.
Click these for
fine adjustments.
(The black rectangular Q
is displayed.)
Line sloped downward to
the right (not displayed in
the window)
Parallel