Instruction manual
Interval Mode Settings
4-26
Number of times condition is satisfied
Specifies how many times a condition is regarded as having been established when a condition specified
above (including the logical operator) is satisfied multiple times. The maximum value is 32767 counts.
Interval Mode Settings
You can set trigger-action details in the dialog box displayed by choosing the Setup menu and then Trigger.
The settings in the above dialog box specify that there are to be 4 recordings, each of which shall begin every
hour on the hour from noon on August 15, 2001 and end in 5 minutes.
Interval
Select this to enable the Interval mode.
Start Time
Specify the date and time when the interval action is to start.
Rec Time
Clicking this displays a dialog box in which you can specify the recording period. The value you set is
displayed in this area.
Interval Time
Specify the interval to wait before recording. (Note that this is not the cycle period.) Clicking this displays a
dialog box in which you can specify the interval. Set the interval time to 5 sec or more when you do
synchronization recording (Refer to “Recording Synchronization” on page 29 in Section 5 “Operations”) or 3
sec when you don’t. (For media recording, many more seconds may be required) The value you set is
displayed in this area.
Enable
the interval mode
Specify the date and time of
starting the interval action
Recording period
Pause period
Number of repetitions