Instruction manual
Repeat Mode Settings
4-23
※ The upper limit(sec) decided by the 96k Hz series sampling frequency and the number of channels is calculated
based on
1Mbyte = 1048576Byte.
16bits AD/24bits AD
96kHz series Pre-trigger upper limit (sec) by channel number
Sampling rate(kHz) 2 4 8 16 24 32
96 103 / 51 51 / 25 25/ N.A. N.A. N.A. N.A.
48 206 / 103 103 / 51 51 / 25 25/ N.A. N.A. N.A.
24 412 / 206 206 / 103 103 / 51 51 / 25 34/ N.A. 25/ N.A.
12 825 / 412 412 / 206 206 / 103 103 / 51 68 / 34 51 / 25
6 1651 / 825 825 / 412 412 / 206 206 / 103 137 / 68 103 / 51
3 3303 /1651 1651 / 825 825 / 412 412 / 206 275 /137 206 / 103
1.5 6606 / 3303 3303 /1651 1651 / 825 825 / 412 550 / 275 412 / 206
N.A.:Not available
CAUTIONS: (Number of analog input ch. + Number of tachometer input ch.) x Sampling Frequency(Hz) x AD
width ≧ 524288
Continuous recording operations might not be done (stopped when memory becomes full
while recoding) when the pre-trigger settings are made as in the above conditions.
Stop Post Trig
Specify the length of the pre-trigger in seconds or in scan units. To switch the units, click a button on the
right. When 0 is entered, Timeout is disabled. Set a value so that it does not exceed the upper limit of the
post-trigger setting.
The upper limit of the post-trigger setting can be calculated as follows. If the media becomes full during
recording, it stops regardless of the setting of post-trigger.
Upper limit value (scan)
= 999999999
Upper limit value (sec)
= 999999999 / Sampling frequency (Hz)