Instruction manual
Input Amp Settings
4-9
AR-LXPA100 Setting Dialog
AR-LXPA100 Setting Dialog
Bal/Unbal: Only a combination of DC/OFF/FLAT selections is applicable at Unbal.
■ At the AR-LXPA100 amp, the sensor power supply voltage is 28 V DC as a standard setting. Contact TEAC
for a 24 V DC setting.
Select the weighting
filter.
A: A filter
C: C filter
FLAT: Flat
Select HPF
(High Pass
Filter).
OFF: No
10Hz: 10 Hz
20Hz: 20 Hz
Select the input range(0.01 V、0.0316 V、0.1 V、0.316
V、1 V、3.16 V、10 V、50V)
Select the coupling mode
AC: AC coupling
DC: DC coupling
Select turning ON or OFF of the power supply
to the sensor connected.
OFF: No supply
4mA: Supply 4 mA constant current
Select: Balanced
or Unbalanced input
Bal: Balanced
Unbal: Unbalanced
Automatically set to DC coupling for all the
8 channels when the unbalanced input is
selected
Confirm input level of every channel
Stop confirming input channel
Set input range automatically