Instruction manual
System Settings
4-3
f
or LX-110
In LX-110, you can select the sampling frequency series of 96k-1.5k and 1k-1/60 only at the upper row. You
also can set a sampling frequency of 96 kHz, 48 kHz, 24 kHz, 12 kHz, 6 kHz, 3 kHz, or 1.5 kHz in 96k-1.5k at
the lower row and set one of 1 kHz、500 Hz、200 Hz、100 Hz、50 Hz、20 Hz、10 Hz、5 Hz、2 Hz、1 Hz、1/2 Hz、
1/5 Hz、1/10 Hz、1/30 Hz、1/60 Hz in 1k-1/60.
for LX-120
In LX-120, in addition to 96k-1.5 and 1k—1/60 series, you can select another sampling frequency from the
following: 100k-1k (100 kHz, 50 kHz, 20 kHz, 10 kHz, 5 kHz, 2 kHz, or 1 kHz) 102.4k-1.28k (102.4 kHz,
51.2 kHz, 25.6 kHz, 12.8 kHz, 5.12 kHz, 2.56 kHz, or 1.28 kHz) 65.536k-1.024k (65.536 kHz, 32.768 kHz,
16.384 kHz, 8.192 kHz, 4.096 kHz, 2.048 kHz, or 1.024 kHz)
Memo
Set to ON when recording or reproducing a voice memo. Voice memo data is recorded as a voice memo file
separately from the data and header files, using 8,000 bytes per second. Note that this data increases even
when the microphone has been removed from the jack.
■ In case both of the media (Memory or Card) and the PC are specified as a destination of recording and setting ON at
the recording of voice memo, the data file of voice memo is created on the media of the LX main unit only, not on the PC.
■ A voice memo is not recorded during the pre-trigger period. In playback, the voice is replayed from the beginning of
the data. So, the voice and data are not synchronized.
Fan
When you set this to OFF, you can stop the cooling fan on the LX-100 for a period of 10 minutes from the
start of recording. This is useful for recording noise. If you have already stopped the fan and recorded data,
wait for about 10 minutes before you again stop the fan and record.
When you set this to ON, the cooling fan is turned to on. However, by clicking the fan stop button on the
toolbar, you can stop the fan while recording. Click again to restart the fan. An accumulated time to stop the
fan within a single recording (from recording start to stop) is 10 minutes. The remaining time to stop the fan
is displayed at the status display. (See "Display of Status Bar" on page 3-4.)
Panel
When you set this to Lock, you can disable the control buttons on the front of the main unit.
Reproducing data
Reproducing voice memo
Pre
-
Trigger