Instruction manual

Starting Program
2-16
When multiple LX-100 series are found in the same segment, the dialog box appears as shown below. In
such a case, select the check box of the LX-100 series to be connected, and click the OK button.
On a real time PC recording of the LX-100 series (LAN model), the speed of the data transfer cannot catch up
to the recording throughput a time unit. In this scenario, the recording will stop automatically when the
memory buffer of the LX becomes full with un-transferred data. It is caused by depending on the PC
specifications and the network traffic. However, the following sampling setting is not applicable for the real
time PC recording.
Sampling Frequency 96 kHz x 8 ch Memo voice ON/OFF
If, by using LX Navi, multiple LX units are connected to a single PC (with IEEE 1394 or LAN), the waveform
settings and the data folder settings of each LX may conflict with others because the LX Navi shares the
common save area. So that every PC has its own LX within a multi environment, use a separate PC for each
LX.
The Main Window will be displayed by starting LX Navi when the connection is completed.
See “Section 3 Introduction to LX Navi”.