Instruction manual

Connector Specifications
6-25
Connector Specifications
DIGITAL CONTROL connector
<Functions>
Contact input: REC FWD, REC, FWD, STOP, PAUSE, event, panel lock, and internal clock
adjustment
Status output: REC, FWD, STOP, PAUSE, event, and panel lock
<Input/Output Circuit>
Input Format L level: 0.4 V or less
H level: Open or 2 V or more
Pulse width: 100 ms or more
Output Format Open drain, maximum sync current: 8 mA
<Connector>
Angled half pitch 36-pin DHA-RC36-R1xxx series
Pin Assignment
Pin No. Signal Function Pin No. Signal Function
1 GND Ground 19 GND Ground
2 RESERVED Reserved 20 RESERVED Reserved
3 RESERVED Reserved 21 RESERVED Reserved
4 GND Ground 22 AGND Reserved
5 RESERVED Reserved 23 AGND Reserved
6 RESERVED Reserved 24 AGND Reserved
7 GND Ground 25 AGND Reserved
8 RESERVED Reserved 26 RESERVED Reserved
9 RESERVED Reserved 27 RESERVED Reserved
10 RTCADJIN Internal clock
ADjustment input
28 NC
11 RECFWDIN REC FWD input 29 NC
12 RECIN REC input 30 RECSTS REC output
13 FWDIN FWD input 31 FWDSTS FWD output
14 STOPIN STOP input 32 STOPSTS STOP output
15 PAUSEIN PAUSE input 33 PAUSESTS PAUSE output
16 EVENTIN EVENT input 34 EVENTSTS Event output
17 PLOCKIN Panel Lock input 35 PLOCKSTS Panel Lock output
18 GND Ground 36 GND Ground
For PANEL LOCK input, the control buttons on the front panel of the LX cannot be used to perform operations.
The first signal locks the control buttons; the second signal releases the lock.
100 ms
ec
or more
Lock
Release
1 s
ec
or more