Instruction manual

Recording Synchronization
5-33
Meaning of displayed items after clicking “Sync Check” button
Status of Check Box
status sync mode Meaning
Check Mark ON CHECK MASTER
Master unit set for
synchronization operation
Check mark ON
[grey background]
OK
SLAVE n
(n is slave no.)
Slave unit set for
synchronization operation
(connection test passed)
Check mark Off NG
SLAVE n
(n is slave no.)
Slave unit set for
synchronization operation
(connection test failed)
Check mark Off NO SYNC Standalone unit set
Check mark Off NOT SUPPORT
Model not supported
for synchronization operation
Unit being used
Red Check mark On
[grey background]
ERROR An error has occurred
Red Check mark On
[grey background]
(USE) Unit being used
Check mark Off
[grey background]
(IP ERR) IP address of the unit is out of group
Once a setting parameter is changed, a “+” symbol is added to the displayed starting portion of “sync mode”.
The “Sync Check” is not available for the unit being used or the one with out-of-group IP address.