Instruction manual

Recording Synchronization
5-31
Operations
You can set the master unit and the slave unit(s) by using the LX Navi.
1
. Start to run LX Navi in PC and the information, such as serial number or etc of LX series, that are
connected in the same segment, will be displayed on the LX selected dialogue (LX Network).
Click the row of “sync select” in a sequence of master, slave1, slave2, …The setting parameters will be
displayed in the area where you clicked (This operation can be omitted the next time.)
Click “Sync Check” button. Confirming / setting the synchronization settings of the specified LX and its
confirmation test of synchronization connection will be conducted as above.
The following figure shows that two units of the LX series are connected in the same group, and that the unit
with the serial no.107100 and no.107366 are assigned as master and slave 1 for each (click the row of
“sync select” in order of master, slave1, as you want.
By clicking “Sync Check” at this time, the synchronization mode setting and the confirmation of the
synchronization connection can be done.
Table of LX selection dialogue (LX Network)
"serial" serial number of the LX series recorder connected in the same segment
"use" Indicates in-use state “ON” or not-in-use state “OFF”
"ip Address" indicates the IP address
"name" indicates the name set on the LX (IEEE1394 model is a fixed name)
"status" indicates the connection status or the results of the confirmation test for the
synchronization connection
"sync mode" indicates the contents of the synchronization settings of the LX main unit
"sync select" The order of master or slave unit (order of click) and their settings are displayed by the
above figure for synchronization operation.