Instruction manual

Recording Synchronization
5-30
Settings and Recording Operations
Use the LX Navi menu of each master/slave unit for the amp and input range parameter settings, the
sampling frequency, and so on. Make sure to use the same sampling frequency and recording media for the
units to be recording synchronized.
Use the LX Navi of the master unit to start, pause, and restart the slave units, which follow these operations
of the master unit.
Connecting Recording Synchronization Cables and Turning on Power
1.
Connect the LX units to be synchronized by using the synchronization cables.
The <SYNCHRO IN> connector and the <SYNCHRO OUT> connector are used for recording
synchronization.
Connect the <SYNCHRO OUT> connector of the first unit (master unit) to the <SYNCHRO IN> connector of
the second unit (slave 1). If you have the third unit (slave 2), connect the <SYNCHRO OUT> connector of
the second unit to the <SYNCHRO IN> connector of the third unit. Then connect another unit (slave N)
accordingly.
2.
In the case of IEEE1394 interface models, use the IEEE1394 cables to connect among the units in a daisy
chain. Connect the PC LX Navi installed PC to one of the units.
In the case of the Ethernet interface model, connect the LX unit through the switching hub. Connect the LX
unit and the LX Navi installed PC to switching hub.
3.
Turn ON the powers of the LX units and then the PC.
SERIAL NO.
MADE IN JAPAN
RECORDING UNIT
12-28V ,
LX-110
6.0-2.6A
TEAC CORPORATION
BATTERY UNIT:BU-81