User manual

S
-99-
COMMON
Lean the cabinet door close and fi ll the above mentioned quantity of descaler at 10
sec intervals into the steam generator
NOTE: Descaling liquid can react very violently with the scale
inside the steam generator!
Should any foam appear at the steam inlet port stop fi lling and
wash the interior cabinet with fresh water.
After fi lling the required quantity remove the hose from the steam inlet port. Pump the
remaining liquid from inside the hose back into the descaler container bottle
Flush and rinse pump and pump hoses with fresh water.
Caution: not rinsing can cause internal corrosion of the pump.
Rinse the cabinet with fresh water.
Follow the further instructions given in the users manual for completing the descaling
User instruction electrical descaler pump
4.
5.
6.
7.
Descaling interrupt SCC:
As long as no descaler was fi lled into the steam generator the „Arrow back“ in window 1 is
still showing.
After the descaler was confi rmed to be fi lled the only way to interrupt the descaling process
is to:
- Switch unit OFF and ON again
- Press „Abort“
- Remaining time of 1:08 will be displayed
- If now the key „Aborted“ is pressed again and the unit is switched OFF and ON again
a remaining time of 23 min will show.
- After another 2 min this time display will drop to 5 min
- Now the steam generator will be fl ushed 2x. After this the „Arrow Back“ will be shown.
- By touching this key the descaling program will be exited
Note: Rinse the cabinet thoroughly with fresh water and operate the unit in steam mode
for some minutes.
- Now the unit can be accessed for cooking again.
Descaling interrupt CM:
- Switch unit OFF and ON again.
- Press core temperature key once.
- Remaining time of 20 min will be shown. During this time the steam generator will be
automatically fl ushed with fresh water and a steam cycle will follow.
Notes: Descaler foot pump is available under service part number 6004.0203