User manual

S
-90-
COMMON
Flash SCC Software
The actual software version can be downloaded from:
www/rational-ag.de/service/technical_documentation/SCC-Line/Software
Software update by USB-stick
USB stick MUST be formatted in FAT (FAT16) format.
NOTE: Most standard USB Flash stick are not suitable for SCC Flash update!
RATIONAL confi gured USB Flash memory stick can be ordered under
part number: 87.00.010
Software can only be updated to the next higher version. Flashing software versions prior to
the existing version is NOT possible!
NOTE!
Software update on a unit with unknown software version (in case a pcb from spare
part stock is used) or in case the external EEPROM was faulty please observe the
procedure on the following page.
For Standard Software Update please proceed as follows:
1. Switch unit on
2. Wait until the operator mode of the SelfCooking Center is displayed.
3. Connect the USB stick with the actual software version to the USB interface of the
Rational SelfCooking Center.
4. Switch unit off and on again.
The unit will display „UPDATE“ followed by „Please don‘t touch“.
After the operator mode of the SelfCooking Center is displayed the USB stick can be
removed from the unit.
Notes: Please make sure your customer has always the latest software on his unit.
Please make sure you have the latest update.exe dated December, 6th, 2004
(12.06.2004) on your USB memory stick.