User manual
-66-
S
S
C
C
1
2
3
4
1
2
3
4
1
2
3
4
10 - Basic Setting
SC Automatic
45sec (20-90sec)
SC Pump duration
60min (20-120min)
Steam heating time
- Activation by touch on dial icon
- Adjust duration with dial
- Confi rm adjustment by touch on
dial icon
12 - Basic Setting
Show mode
ON - OFF
- Activation by touch on dial icon
- Adjust with dial
- Confi rm adjustment by touch on
dial icon
15 - Basic Setting
Quench. Temp. OFF
120°C (20- 130°C)
248°F (68 - 266°F)
- Press dial icon
- Adjust to new temperature
- Confi rm adjustment by touch on
dial icon
9 - Basic Setting
Volume Steam Generator NEW
Reset After manual
descaling
Reset After changing
steam generator
- since Software version 01-07-02
- Reset
(press „for 5 sec.)
in
window 3 activates SC-automatic
to reset the CDS indication.
- Reset
(press „for 5 sec.)
in
window 4 activates SC-automatic
to get the new reference volume
after steam generator
change
11 - Basic Setting
SC Pump
CONTINUOUS
Puls
- Activation by touch on dial icon
- Adjust with dial
- Confi rm adjustment by touch on
dial icon
14 - Basic Setting
Quench. Temp. Moist Heat
70°C (20- 130°C)
158°F(68 - 266°F)
- Press dial icon
- Adjust to new temperature
- Confi rm adjustment by touch on
dial icon
13 - Basic Setting
Quench. Temp. Dry Heat
90°C (20- 130°C)
194°F (68 - 266°F)
- Setting quenching temperature
- Press dial icon
- Adjust to new temperature
- Confi rm adjustment by touch on
dial icon
16.1 - Basic Setting
Service Phone
08191-327_
0 1 2 3 4 5 6 7 8 9
Delete Store
- Change number and confi rm by
pressing central dial
- „Delete“ erases last entered
number
- Confi rm entry by pressing „Store“
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
SCC Basic Settings (switch OFF - ON after adjustment)