Training Manual Diagnostic and Troubleshooting SCC Line SelfCooking Center - Combi Master Edition 11-2006 -1-
Training Manual Diagnostic and Troubleshooting SCC Line Edition 11-2006 General hints: Isolate the appliance from mains supply before opening the appliance When working with chemicals, i.e.
Part 2: Topic: SCC Technique Page: 1. 2. 3. 4. 5. 6. 4. 5. 6. 7. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27.
S C M CM Technique from 04 - 2004 Steam Hot Air Combi Steam Low Temperature Steam Finishing Cool Down Cabinet temperature display Cabinet temperature setting Timer Core temperature Time - Core temperature display Time - Core temperature setting -4-
S CM Technique from 04 - 2004 B1 F4 B3 S2 B5 F3 M1 M4 B2 Y2 Y1 B1 B2 B3 B5 Thermocouple cabinet Thermocouple quenching / Steam control Thermocouple core temperature Thermocouple steam generator (preheating, 180°C (356°F) max) F3 F4 Safety temperature limiter steam generator 160°C Safety temperature limiter cabinet 360°C Y1 Y2 Solenoid valve filling Solenoid valve quenching M1 M4 Fan motor (without jumper) SC-pump S2 Level electrode CM 201/202 only: M2 Fan motor top (with jumper) -5- C M
S Water level control Steam Generator C M S2 B5 S2 F3 V AC M4 B2 Y1 Y2 Center S2 ==> Ground: 2 - 6V AC: water level too low steam heating must switch OFF solenoid valve filling Y1 ON Center S2 ==> Ground: 0V AC: water level reached steam heating can switch ON solenoid valve filling Y1 switched OFF Every 2 minutes steam elements will switch off for water level control X12 Notes: -6-
S Steam Control CM from 04 - 2004 Intelligent steam control via quenching sensor B1 1. Filling of interior cabinet based on time and temperature control of B1 cabinet sensor B2 Y1 2. After steam saturation inside cabinet steam will also fill quenching chamber Y2 °C / °F 70°C (158°F) 3. Depending on the frequency of temperature raise of the quenching sensor B2 the duration of the next steam supply is calculated.
S Key code CM from 04 - 2004 C M 1. Cleaning program A) B) C) D) E) F) G) Cool down cabinet below 60°C Spray inside cabinet with Rational cleaner Close cabinet door Select „Cool Down Press core temperature key for 10 sec. „CLEn“ will show in cabinet temperature display Press timer key 1x; Cleaning program starts automatically (open cabinet door and rinse interior cabinet after 40 min.) Close door again. Since Software version C1-06-05 a 10 min step hot air will follow to dry the interior cabinet.
Key code CM from 04 - 2004 4. Changing temperature display from °C to °F A) Select any mode C) Press timer and core temperature key simultaneously for 10 sec.
S C M CM PCB (42.00.004) from 04-2004 CM PCB (42.00.047) from 02-2006 (without transformer) 42.00.004 X2 B3 Core temperature X3 B1 Interior cabinet X4 B2 Quenching / Steam control X6 B5 Steam generator X7 ON - OFF switch X8 Buzzer X12 Level electrode X 16 power supply from transformer (42.00.
Motor for CM 40.00.274 Jumper LED Jumper 40.01.581 is used on floor model 201 and 202 for top position motor only! Jumper is not used on models 61 - 102 with one motor only! (Service 34 will be shown!) LED code fan motor SCC and CM from 04/2004 Reason Remedy 1x Motor doesn’t start, no changing signal from hallsensor Check for motor blockage or change motor. 2x Voltage too low on motor pcb Check supply voltage or change motor. 3x Voltage too high on motor pcb Check supply voltage or change motor.
S C M Mode: Steam 100°C (212°F) Temp.
Mode: Low temperature steam Temp. range 30-99°C (86-210°F) Function Step Signal Remark Responsible sensor Note: Below 100°C (212°F) fan at lowest speed when no energy required for longer than 2 minutes. -13- 1 Select vario steam mode (Temp.
S C M Mode: Combination Temp. range 30-300°C (86-572°F) Function Step Signal Remark Responsible sensor Note: Below 100°C (212°F) fan at lowest speed when no energy required for longer than 2 minutes. -14- 1 Select Combination mode (Temp.
Mode: Finishing Temp. range 30-300°C (86-572°F) F Function Step Signal Remark Responsible sensor Note: Below 100°C (212°F) fan at lowest speed when no energy required for longer than 2 minutes. -15- 1 Select Finishing (Recom. Temp.
S C M Mode: Hot Air Temp. range 30-300°C (86-572°F) Function Step Remark Signal Responsible sensor Note: Below 100°C (212°F) fan at lowest speed when no energy required for longer than 2 minutes. -16- 1 Select Hot Air (Temp. 30-300°C (86-572°F)) 2 Select time or core temperature 3 Close cabinet door Reed switch S3 4 Timer starts at once Logic on PCB 5 Hot Air supply until set temperature inside cabinet is reached Cabinet sensor B1 SSR active: 12VDC X24:(7-8)+(3-4) SSR not act.
Service level CM from 04 - 2004 42.00.004 2 AT 0,1 AT F1 F2 A) Transformer Switch unit ON X7 1 2 B) On operator PCB set DIP switch 1 to „ON“ position 3 X20 on X19 1 4 1 42.00.047 C) 2 AT F6 X16 Select service package with timer dial: 2 AT F6.
Service level: dP -- Diagnostic Program S C M Cabinet display Timer display Comment dP # Description dP 1 Software Version dP 2 B1 Cabinet sensor X3 actual value max value Reset by pressing for 5 sec. + dP 3 B2 Quenching sensor X4 actual value max value Reset by pressing for 5 sec. + dP 4 B3 Core sensor X2 actual valuet max value Reset by pressing for 5 sec. + dP 5 B5 Steam generator sensor X6 actual value max value Reset by pressing for 5 sec.
S C M Service Level: rt -- Running Time Timer display: 1-999 Temp. display: >1000 Comment rt # Description rt 1 Total S3 door openings rt 2 Total time Y1 valve filling min rt 3 Total time Y2 valve quenching min rt 4 Total time M4 SC-pump min rt 5 Total time steam heating time hrs rt 6 Total time hot air heating time hrs rt 7 Total time steam mode hrs Reset by pressing for 5 sec. Reset by pressing for 5 sec. Reset by pressing for 5 sec. Reset by pressing for 5 sec.
S Service level: SE -- Basic settings C M Select desired step with timer dial (fan motor and heating elements are automatically OFF) Activate selected step with timer key SE 1 Steam heating time since last SC-Automatic Press time and core key simultaneously for 5 seconds to set steam heating time to preset steam heating time plus 1 minute ==> test function for SC-Automatic Preset Steam heating time until SC-Automatic (default 45min) SE 2 + Press time key and adjust preset steam heating time from 20 -
Service Level: SE -- Basic settings SE 9,10,11 + SE 12,13,14 + SE 15,16,17 + Adjusting speed of blower motor steam (+/ -10%) (After blower speed adjustment the original rpm is shown in the temp.
S C M Service level: F -- Function test NOTE: In Function test components are NOT protected against overload! Function Connection I/O PCB X24:(1-2) Cabinet Display F1 Steam 50%, Electric unit actual temp. B5 steam generator F2 Steam 100%, Electric unit X24:(1-2)+(5-6) actual temp. B5 steam generator F3 Hot Air 50%, Electric unit X24:(7-8) actual temp. B1 cabinet F4 Hot Air 100%, Electric unit X24:(7-8)+(3-4) actual temp. B1 cabinet F5 Steam, Gas unit BUS actual temp.
S Service level: F -- Function test NOTE: In Function test components are NOT protected against overload! F # Function Connection Cabinet I/O PCB Dispaly Time Display Comment F19 Steam blower motor MIN rpm BUS Actual blower rpm Set CO2 value Check CO2 value only F20 Steam blower motor Start rpm BUS Actual blower rpm BUS Actual blower rpm Set CO2 value Adjust CO2 value with CO2 screw on gas valve F22 Hot air blower motor, top BUS MIN rpm Actual blower rpm Set CO2 value Check CO2 value onl
S C M Service Level: ER -- Error code history Since software version C1-07-01 the last 10 error messages are shown. Er Er1 Er2 Er3 --Er10 When Timer key is pressed the error code will be displayed, i.e.
Failure Codes CM from 04-2004 Int. cab. display H2o CHnG Timer display Timer display OPEn PoL Int. cab. display (E -press core temp.
CM Gas from 04 - 2004 S C M B5 B1 F4 F3 B3 S2 B11 M9 Y11 M1 A5 M4 B12 M8 Y12 B2 Y1 A5 B1 B2 B3 B5 B11 B12 F3 F4 M1 M4 M8 M9 Y1 Y2 Y11 Y12 S2 Y2 Ignition module (Steam and Hot Air) (without jumper) Thermocouple interior cabinet Thermocouple quenching / Steam control Thermocouple core temperature Thermocouple steam generator Ignition/monitoring electrode steam Ignition/monitoring electrode hot air Safety thermostat steam generator 135°C Safety thermostat interior cabinet 360°C Fan motor SC-pum
Basic info about CM Gas from 04-2004 Identification of the different gas burners / Gas blowers: CM 201 - 202 CM 61 - 62 - 101 - 102 Steam Blower (ignition box fitted) Hot Air blower top (ignition box not fitted) Hot Air blower bottom (ignition box fitted) Ignition box of Hot Air Blower, Bottom (201-202): Ignition box Jumper must ONLY be set on Ignition Box for Hot Air Blower Bottom (201 - 202) Gas valve components Measuring test point for gas flow pressure Gas supply Compensation hose CO2 Srew -27- S
S C M Sequence of events of Steam / Hot Air Burner (SCC as well as CM) Max RPM µA RPM 8 Flame current Start RPM 5 4 3 2 1 Start up Time 0 1 2 3 Pre purge 4 5 6 7 8 9 Ignition Flame control Min RPM Pre ignition -28- F l a m e c u r r e n t in µA 6 Burner running 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 sec Ignition box gets heat demand over the BUS cable Heat demand Start - pre purge about.
Check Gas Type / Gas Conversion: CM Gas from 04-2004 Whenever working on any gas component like: Gas valve, gas blower and / or changing connected type of gas, a detailed flue gas analysis MUST be done using adequate CO and CO2 measuring equipment! This shall ONLY be done by trained technicians! Always check appliance for possible gas leakages! S C M Danger: Changing the gas type of your SelfCooking Center or Combi Master shall only be done if you have a flue gas analyser at hand.
S Changing installation altitude: CM gas from 04-2004 C M Note: The altitude settings of 0-499 and 500-999m are identical. Therefore resetting of installation altitude needs to be done only when installing above 1000m (3280ft) or below sea level (i.e. Red Sea) A) Select any mode and cooking time B) Open control panel on C) SE 1 2 3 4 Set DIP switch 1 on PCB to „ON“ position D) With timer dial select: „SE“ = Settings.
Flue gas analysis: CM gas from 04-2004 Before you carry out a flue gas analysis check input gas flow pressure when burner is running • Switch on unit. Select any mode and cooking time.
S C M Flue gas analysis: CM gas from 04-2004 F 19 L) Select position F19 with timer dial and enter „Steam MIN“ with timer key. Activate position F19 with core temperature key; M) NOTE: in this position core temp. key is used as a switch and will automatically deactivate after 4 minutes.“ N) Carry out a CO2 measurement to cross-check CO2 value only.
Type of gas SCC - CM Values for burner adjustments of gas units SCC / CM Steam Burner 61 18 - 25 mbar 62 18 - 25 mbar Natural Gas 101 18 - 25 mbar High 102 18 - 25 mbar (G20) 3,9 mm 3,4 mm 9,4% 8,0% 18 - 25 mbar 9,4% 7,9% 18 - 25 mbar 3,3 mm 9,4% 7,7% 4,1 mm 9,4% Hot Air Burner - Bottom Side (only at 201-202) CO2 at "MAX" rpm ± 0,2% CO2 at "Min" rpm - 0,2% / + 0,5% 3,8 mm 3,5 mm 9,4% 8,3% 9,4% 8,0% 18 - 25 mbar 3,3 mm 9,4% 7,7% 8,4% 18 - 25 mbar 3,5 mm 9,4% 8,6% 9,4% 9,5
S C M Changing Gas blower speed (MAX, Start, MIN rpm): CM gas from 04-2004 (as from Software C-06-03): This setting shall ONLY be done by specially trained and RATIONAL approved technicians.
SCC Control Panel Notes: S S C C -35-
Up to Software version SCC 01-07-12 only! SelfCooking Control Mode - Level 1 SelfCooking Control Mode - Level 3 SelfCooking Control Mode - Level 2 S S C C 1 1 2 2 3 3 4 Universal roasting Roasting with crackling Soft roasting Soft cooking Overnight roasting Overnight cooking 4 1 Overnight roasting 2 Low High rare well done 3 4 preheat Back to previous level help guide line for selected setting CleanJet, HACCP, Delta T, E1/2 Start time, CDS, Descaling, Settings Selection of core
Up to Software version SCC 01-07-12 only! Combi Steamer Mode Functions Settings S 1 1 1 10:24 HACCP CleanJet 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 2 2 3 4 08/22/03 Start time Duration 24 h h:m m:s 2 200°C 3 am/pm °C / °F 22.08.03 3 CDS english 4 Prog 4 Settings Setting of : time, Date, time format, °C/°F etc.
This display since Software version SCC 02-01-01 only! SelfCooking Control Mode - Level 1 SelfCooking Control Mode - Level 2 SelfCooking Control Mode - Level 3 S S C C 1 1 2 2 3 3 4 4 13:45 1 roast braise roast with crackling gentle roasting overnight roasting gentle cooking 2 3 medium 4 13:45 overnight roasting 62°C close door Large roast Potato product Pan fries Egg dishes/Desserts Poultry Bakery products Fish Finishing Side dishes Help: guide line for selected setting;
This display since Software version SCC 02-01-01 only! Combi Steamer Mode Functions Settings S 1 1 CleanJet 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 2 1 10:24 2 2 200°C 3 24 h 10/22/06 start time 3 h:m m:s °C / °F 22.10.
Prog select program name with central dial S S C C 1 Clean manual 2 new level control copy change new give program name (blank - between _ and @ copy existing SCC process or program can be copied and get an index number, i.e. 1; name can be edited and changed; change Change parameter and / or cooking mode of program in a non-active program; 3 4 delete confirm change by: delete selected program flashes; confirm delete by pressing again 1. Give program name 2. Store 3.
Notes: S S C C -41-
SCC Electric from 04-2004 B1 F4 B6 M3 S4 S S C C S2 B5 P1 F3 M1 B4 M4 S11 B2 Y1 Y3 Y2 M6 M7 B1 B2 B4 B5 B6-B11 F3 F4 Y1 Y2 Y3 M1 M3 M4 M6 M7 S2 S4 S11 S12 P1 S12 Thermocouple interior cabinet Thermocouple quenching Thermocouple humidity Thermocouple steam generator (preheat, 180°C (356°F) max) Thermocouples core temperature Safety thermostat steam generator 160°C (320°F) Safety thermostat interior cabinet 360°C (680°F) Solenoid valve filling Solenoid valve quenching Solenoid valve moistening F
Notes: S S C C -43-
SCC Operator pcb (42.00.
Measuring points I/O PCB SCC (40.00.049) Wires of pcb edge connectors are pointing to component side of pcb! Motor drain valve Micro switch drain valve 12 V DC SSR SSR puls (USA version) S SSR2: BSSR2: ASSR1: BSSR1: A+ 12V 1 X 21.1 2A T 2A T 12 V DC 230 V 16 V DC _ + M 12 V DC S C C X 26.1 X 23.1 230V K1:L1 input F2: N X 25.1 UltraventVent . X 24.1 X6.1 S12 M7 12 V DC S3 X 20.1 X 27.1 2 12 V AC T1 A1 X 19.
Motor for SCC / CM S S C C Jumper LED Jumper 40.01.581 is used on floor model 201 and 202 for top position motor only! Jumper is not used on models 61 - 102 with one motor only! (Service 34 will be shown!) LED code fan motor SCC and CM from 04/2004 Reason Remedy 1x Motor doesn’t start, no changing signal from hallsensor Check for motor blockage or change motor. 2x Voltage too low on motor pcb Check supply voltage or change motor.
Notes: S S C C -47-
S S C C SCC Units: Sequence of Events Mode: Wet heat (98-103°C (208-218°F), set temperature) Function step Responsible sensor Signal Remark Note: Steam heating only active when humidity flap (S4) is in closed position! -48- 1 Select Wet heat (Temp 98-103°C (208-218°F)) 2 Select time or core temperature 3 Close cabinet door Reed switch S3 Door open: Door closed: 12VDC X27:(1-2) 0VDC X27:(1-2) 4 Check water level inside steam generator Level electrode S2 inside Steam Generator X12:(1-4) X1
SCC Units: Sequence of Events Mode: Low temperature steam; (30-97°C (85-207°F), set temperature) Function step 1 Select Wet heat (Temp 30-97°C (85-207°F) 2 Select time or core temperature 3 Close cabinet door Responsible sensor Signal Remark Note: Steam heating only active when humidity flap (S4) is in closed position! Below 98°C fan at lowest speed when no energy required for longer than 2 minutes.
S S C C SCC Units: Sequence of Events Mode: Forced Steam104-130°C (219-266°F), set temperature) Function step Responsible sensor Signal Remark Note: Steam heating only active when humidity flap (S4) is in closed position! -50- 1 Select Wet heat (Temp 104-130°C (219-266°F)) 2 Select time or core temperature 3 Close cabinet door Reed switch S3 Door open: Door closed: 12VDC X27:(1-2) 0VDC X27:(1-2) 4 Check water level inside steam generator Level electrode S2 inside Steam Generator X12:(1-4
SCC Units: Sequence of Events Mode: Combi Steam 141-300°C (286-572°F), set temp.
S S C C SCC Units: Sequence of Events Mode: Finishing (30°-140°C (85-284°F), set Temp. Function step Responsible sensor Signal Remark Note: Steam heating only active when humidity flap (S4) is in closed position! Below 98°C fan at lowest speed when no energy required for longer than 2 minutes. -52- 1 Select Wet and Dry heat (Temp.
SCC Electric: Sequence of Events Mode: Dry heat 30°-300°C (86-572°F), set Temp. -53- Responsible sensor 1 Select Dry heat Temp. 30-300°C (86-572°F) Note: Below 98°C fan at lowest speed when no energy required for longer than 2 minutes.
Service level SCC A) X7 X8 A2 SCC pcb S Switch on unit X 12 B) 1 S C C Set DIP 1 on operator PCB to „“ON““ position on 2 3 4 X 11 X5 X2 X6 X4 X3 A3 Add On pcb C) Press service key D) On the displays the following available Service - modules will be shown X1 X 50 Battery ON Window 1 3V Diagnostic 2 LED 1 2 3 Window 2 Running Times X 09 X 51 3 X 53 X 54 X2 1 X 52 RS 232 Window 3 X 10 Basic Settings 4 Window 4 E) Activate selected service module by push on display or
Notes: S S C C -55-
SCC Diagnostic Mode overview 1 DIAGNOSTIC Diagnostic 2 1 - Cabinet B1 S S C C Running Times 3 2 - Quenching B2 Basic Settings 4 3 - Not used Function Test 4 - Humidity B4 5 - Steam Generator B5 1 6-11 - Core Temp B6-11 1 - Diagnostic 2 12 - Temperature 13 - Level Electrode S2 3 14 - Door Contact S3 4 Cabinet B1 130°C act Reset 15 - Clima 16 - Clima Status 17 - Clima Motor 18 - Hot Air 1 19 - Steam 2 160°C 20 - SC Automatic 3 32 min 21 - Volume 4 22 - M6 CleanJet pump Y2 Quenc
SCC Diagnostic Mode 1 2 3 1 1 - DIAGNOSTIC 2 Cabinet B1 130°C act Reset 345°C max“ - Temp. range: -30 - 340°C (-22 - 644°F) - 900°C (655°C until SW version 01-07-08) broken thermocouple or loose plug - to reset max value press RESET 1 95°C max“ Reset 130°C act Reset - Temp. range: -30 - 340°C (-22 - 644°F) - 900°C (655°C until SW version 01-07-08) broken thermocouple or loose plug - to reset max value press RESET 345°C max“ 3 Steam Generator B5 104°C act Reset 115°C max“ - Temp.
SCC Diagnostic Mode 1 1 1 15 - DIAGNOSTIC 2 S C C 3 2 Clima P1 - B4 - RPM S Default 0,48V 16 - DIAGNOSTIC out 2,24V 4 B4 85% rpm 145°C 1850 Default: 0,4-0,55V At standard speed: Out ca. 1,3 - 1,6V Combi 200°C (392°F) Out ca. 1,5 - 1,9V Steam 100°C (212°F) Out ca. 2.
SCC Diagnostic Mode 1 2 24 - DIAGNOSTIC Service error history 1 2 25 - DIAGNOSTIC Gas error history S 3 i.e. (1) Service 10 3 Gas 1 4 4 0: 09:10.05 9:17 32 - since software version 01-07-09 - since software version 01-07-09 Indication of the last 10 stored service error messages Indication of the last 16 stored ignition box error messages including date and time.
SCC Running Times overview 1 Running Times S Diagnostic 2 1 - S3 Door openings S C C Running Times 3 2 - S12 Ball valve openings Basic Settings 4 3 - Y1 Valve filling Function Test 4 - Y2 Valve quenching 5 - Y3 valve moistening 1 1 - Running Times 6 - M4 SC pump 2 S3 Door Openings 7 - M6 Cleaning pump 3 219 8 - M7 Ball valve 4 9 - Steam heating time Reset 10 - Hot air heating time 11 - Steam mode 12 - Hot air mode 13 - Combi Steam mode 14 - Vario steam mode 15 - Finishing mode 16.
SCC Running Times 1 2 Y2 Valve quenching 1460min 1 2 3 Reset 2 3 5 - Running Times Y3 valve moistening 48min 7 - Running Times M6 Cleaning pump 315min 4 Indication in minutes Reset possible 6 - Running Times 2 M4 SC pump 3 Indication in minutes Reset possible 1 8 - Running Times 2 M7 Ball valve 3 715min 4 55min Reset Indication in minutes Reset possible 1 9 - Running Times 2 Steam heating time 3 4hrs 4 4 Reset 1 Reset Indication in minutes Reset possible 1 Indica
SCC Running Times 1 10 - Running Times 2 1 S C C 3 Steam mode Hot air mode 4hrs 4hrs 12 - Running Times 3 3 4 1 2 2 Hot air heating time S 11 - Running Times 4hrs 4 4 Reset Indication in complete houres Reset NOT possible Indication in complete houres Reset possible 1 13 - Running Times 1 2 2 3 4 1 16.
Notes: S S C C -63-
Overview Basic Settings NOTE: To validate changes made, switch unit OFF and ON again! 1 Basic Setting Diagnostic S S C C 11 - Calibration 1.
SCC Basic Settings (switch OFF - ON after adjustment) 1 1 1 1- Basic Setting 2 Calibration 1 1.2 - Basic Setting Start 2 - Basic Setting 2 2 Drain valve (Dv) 3 4 B1 99°C B4 95°C Step 90 P1 1,55V RPM 1550 Error 0 NOTE: - To prepare unit for calibration run, see page 64 - When error is shown switch off and follow Error messages for repair. Afterwards start calibration run once again. 1 3 - Basic Setting 2 3 3B/P (G30) Steam Hot air Top Hot air Bot.
SCC Basic Settings (switch OFF - ON after adjustment) 1 2 S S C C 3 4 9 - Basic Setting Volume Steam Generator NEW Reset After manual descaling Reset After changing steam generator - since Software version 01-07-02 - Reset (press „for 5 sec.) in window 3 activates SC-automatic to reset the CDS indication. - Reset (press „for 5 sec.
SCC Basic Settings (switch OFF - ON after adjustment) 1 16.2 - Basic Setting ChefLine Phone 2 1 1 17 - Basic Setting 2 2 08191-327_ 18 - Basic Setting Subnet mask IP Address S 3 3 3 0123456789 4 4 4 Delete Store - since SW 01-07-11 - Change number and confirm by pressing central dial - „Delete“ erases last entered number - Confirm entry by pressing „Store“ 168.65.8.
Overview Function test 1 Function Test S S C C 1 Steam (Dampf) 50% (Gas - not used) 2 Steam (Dampf) 100% (Gas - Dampf Burner) 3 Hot Air 50% (Gas - Burner top) Diagnostic Diagnose 2 Running Times Laufzeiten 3 Basic Settings Grundeinstellungen 4 Function Test Funktionstest 4 Hot Air 100% (Gas - Burner bottom) 5 Fan motor top 1 6 Fan motor bottom 5 - Function Test 2 7 Solenoid valve fillling Y1 Fan Motor top 3 8 SC Pump M4 4 9 Solenoid quenching Y2 START Speed 4 1800 rpm Actual Speed 1800
Function test 1 2 1 1 - Function Test 2 Steam 50% Start 3 1 2 - Function Test 2 Steam 100% (Gas: see below) Start 3 3 0-1 0-1 4 Temperature B5 103°C Hot Air 50% (Gas: see below) Start S 0-1 4 4 Temperature B5 3 - Function Test Temperature B1 103°C 185°C - Electric units: Steam heating 50%; - Electric and gas units: Steam heating 100%; - Gas units: not used Indication gas units (window 2): - Actual temperature of B5 „Steam Gas-Burner“ Actual temperature of B5 Attention: Parts are
Function test 1 2 S S C C 1 10 - Function Test Solenoid moistening Y3 2 Start 3 1 11 - Function Test Humidity flap motor M3 12 - Function Test 2 CleanJet Pump M6 Start 3 3 0-1 0-1 4 0-1 4 4 End switch S4 Activation of solenoid valve moistening Y3 Start 1-0 S4 shows 1 = Flap closed S4 shows 0 = Flap open Activation of CleanJet Pump M6 1 13 - Function Test 2 Drain Valve Motor M7 Start 3 Direction 1 -2 4 End switch S12 1-0 Direction 1: Clockwise Direction 2: Counter clockwise
Function test 1 1 17 - Function Test 2 Buzzer T2 2 Start 1 18 - Function Test Interior light 2 Start 19 - Function Test Display light Start S 3 3 3 0-1 0-1 4 4 4 - Activation of buzzer T2 - Activation of interior cabinet light 1 20 - Function Test 1 21 - Function Test 2 Exhaust hood 2 Sicotronic 3 0-1 Start 3 0-1 4 4 - Relay on pcb - Relay on pcb -71- Start - Testing of all display lights by pushing and holding Start key.
Overview Service messages S S C C Service 10 Service 11 Service 12 Service 13 Service 14 Service 15 Service 16 Service 17 Service 18 Service 19 Service 20 Service 21 Service 22 Service 23 Service 24 Service 25 Service 26 Service 27 Service 28 Service 29 Service 30 Service 31 Service 32 Service 33 Service 34 SC pump CDS Sensor CDS Sensor no signal Steam generator Level electrode - Water Free PCB with old sofware EEPROM faulty Free Free Thermocouple B1 Cabinet Micro switch Clima Plus Free SSR steam SSR ho
Service messages SCC 1 Service 10 1 - Maintenance needed 2 Appears for 30 sec. after switch ON Display can be cancelled by touch SC-automatic didn‘t pump off Check SC-pump - Service 13 2 Maintenance needed Appears for 30 sec. after switch ON Display can be cancelled by touch Water level o. k.
Service messages SCC 1 Service 23 1 (Short circuit SSR Steam) 2 S S C C No function Switch unit off - Since SW 01-07-09 only! - Display at once when: Temp. B5 raises above 100°C (212°F) for 60sec. without energy demand - Intermittent buzzer 30 sec - Unit without function 1 Service 26 No function 1 2 No function Switch unit off - Since SW 01-07-09 only! - Display at once when: Temp.
Notes: The last 10 error messages can be seen in Diagnostic mode 24 „Service error history“ S S C C -75-
Calibration SCC Calibration at the customers site must be done under the following conditions: Changing the pcb, extrenal EEPROM, B4 humidity sensor, Pressure sensor P1, replacing the air baffle or divider plate between the 2 fan motors of a floor model, fan motor, detaching of the fan wheel and installation of the appliance above 1000m (3000ft) above sea level or below sea level (dead sea). S S C C Basic condition Temperatures: Cabinet sensor B1 B1 <40°C Quench.
Calibration SCC Step Unit status: 60 (min: 4x20sec; max: 4x180sec) Controlling with all 4 fan speeds: • Steam Heating: ON 50% • Motor: ON • Humidity flap: Closed Error code In case of „20“ check: In diagnostic mode: P1, B4, rpm 70 (4x 30 sec) Measuring at all 4 fan speeds: Calibration value: Steam • Heating: ON 50% • Motor: ON • Humidity flap: Closed In case of „60“ check: In diagnostic mode: P1, B4, rpm Reason: 20 Value out of allowable range; 71 Max time of 4x180sec exceeded 60 Calibration
S S C C Control Drain Valve 54.00.
Notes: S S C C -79-
SCC Gas from 04-2004 B5 B1 F4 F3 B6 M3 S2 S4 S S C C B11 P1 M9 Y11 M1 A5 B4 M4 B12 M8 Y12 S11 B2 Y1 Y3 Y2 M6 M7 A5 B1 B2 B4 B5 B6 B11 B12 F3 F4 Y1 Y2 Y3 Y11 Y12 M1 M3 M4 M6 M7 M8 M9 S12 Ignition module Thermocouple interior cabinet Thermocouple quenching Thermocouple humidity Thermocouple steam generator Thermocouple core temperature Ignition/monitoring electrode steam Ignition/monitoring electrode hot air Safety thermostat steam generator 135°C Safety thermostat interior cabinet 360°C S
Notes: S S C C -81-
Basic info about SCC Gas from 04-2004 Identification of the different gas burners / Gas blowers: SCC 201 - 202 S S C C SCC 61 - 62 - 101 - 102 Steam Blower (ignition box fitted) Hot Air blower top (ignition box not fitted) Hot Air blower bottom (ignition box fitted) Ignition box of Hot Air Blower, Bottom (201 - 202): Ignition box Jumper must ONLY be set on Ignition Box for Hot Air Blower Bottom (201 - 202) Gas valve components Measuring test point for gas flow pressure Gas supply Compensation hose CO2 S
Sequence of events of Steam / Hot Air Burner (SCC as well as CM) Max RPM µA RPM 8 Speed of burner blower motor in U/min 6 Flame current Start RPM 5 4 3 Min RPM 1 Start up Time 0 1 2 3 Pre ignition -83- 2 Pre purge 4 5 6 7 8 9 Ignition Flame control F l a m e c u r r e n t in µA 7 Burner running 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 sec Ignition box gets heat demand over the BUS cable Heat demand Start - pre purge about.
Check Gas Type - Gas conversion : SCC Gas from 04 - 2004 Whenever working on any gas component like: Gas valve, gas blower and / or changing connected type of gas, a detailed flue gas analysis MUST be done using adequate CO and CO2 measuring equipment! This shall ONLY be done by trained technicians! Always check appliance for possible gas leakages! S S C C Danger: Changing the gas type of your SelfCooking Center or Combi Master shall only be done if you have a flue gas analyser at hand.
Adjustment of installation altitude above sea level SCC Gas from 04 - 2004 Note: The altitude settings of 0-499 and 500-999m are identical. Therefore resetting of installation altitude needs to be done only when installing above 1000m (3280ft) or below sea level (i.e.
Flue gas analysis: SCC gas from 04-2004 Before you carry out a flue gas analysis check input gas flow pressure when burner is running • Switch on unit. Select any mode and cooking time.
Flue gas analysis: SCC Gas ab 04 - 2004 1 H) 14 - Function Test 2 Gas Steam Blower Start/Stop I) 3 Max 4 CO2 See list FC 5,5 xxx rpm Press key and select „Min“ speed. Activate the burner with the „Start“ key. Note: Start key is used as a switch and will automatically deactivate after 4 minutes Display 4 indicates the desired CO2 value, e.g. 9,2%, flame current, i.e. 5,2μA and the corresponding rpm of the blower motor.
S S C C Type of gas SCC - CM Values for burner adjustments of gas units SCC / CM Steam Burner 61 18 - 25 mbar 62 18 - 25 mbar Natural Gas 101 18 - 25 mbar High 102 18 - 25 mbar (G20) CO2 at "MAX" rpm ± 0,2% CO2 at "Min" rpm - 0,2% / + 0,5% 3,8 mm 3,5 mm 9,4% 8,3% 9,4% 8,0% 18 - 25 mbar 3,3 mm 9,4% 7,7% 8,4% 18 - 25 mbar 3,5 mm 9,4% 8,6% 9,4% 9,5% 8,2% 8,8% 18 - 25 mbar 3,4 mm 18 - 25 mbar 3,3 mm 9,4% 9,4% 7,8% 8,7% CO2 at "Min" rpm - 0,2% / + 0,5% 3,9 mm 3,4 mm 9,4% 8,0%
Changing gas blower speed (MAX, Start, MIN rpm) SCC Gas from 04 - 2004 A) - Switch unit ON - Open control panel - Set DIP switch 1 on PCB to „ON“ position on 1 2 3 4 B) At Basic Settings select i.e. position 5 - Gas Blower Steam Gas Blower Steam C) The factory stored blower speed is shown at MAX, Start und MIN. 1 5 - Basic Setting 2 Gas Blower Steam 3 4 Act. rpm xxxx Start rpm xxxx MIN rpm xxxx MAX rpm xxxx D) To change the rpm of MAX, Start and MIN, select the desired step.
Flash SCC Software The actual software version can be downloaded from: www/rational-ag.de/service/technical_documentation/SCC-Line/Software Software update by USB-stick USB stick MUST be formatted in FAT (FAT16) format. NOTE: Most standard USB Flash stick are not suitable for SCC Flash update! RATIONAL configured USB Flash memory stick can be ordered under part number: 87.00.010 S COMMON Software can only be updated to the next higher version.
Notes: S S C C -91-
Changing SCC pcb / changing SCC EEPROM / Software update Changing pcb (pcb defectice) Green LED on main pcb ON? S Standard Software update EEPROM Data faulty (no display of serial number, type) Service 17 Yes Service 16 (from software 01-07-09) Isolate unit from power supply (Disconnect control fuses) NO COMMON check pcb transformer primary and secondary voltage (12VAC) and plug connectors changing pcb EEPROM data faulty replace pcb, do NOT connect EEPROM disconnect old EEPROM Reconnect unit t
Notes: COMMON S -93-
Software update CM units with Flash-Box 87.00.037 S COMMON For downloading unit software from PC to CM flash box the program „Megaload“ must be installed on the PC. This program is available on the Rational Service internet page under: „Technical documentation/Software update SCC-Line/CM“. For installation on the PC proceed as follows: A) Download Zip file to PC B) Open Zip file C) Start the program Setup.exe and follow the description on the screen.
Copying unit software from PC to CM Flash-Box - Open lid of the Flash-Box - Set DIP - switch 2 to „ON“. (other switches remain in the off position) 2. Connect RS 232 adapter cable (item 2) to Flash-Box and to the selected interface (e. g. COM 1) of the PC 3. Start program Megaload and open flash software (e.g.: C-1-06.02.hex) 4. Connect USB-cable (item 3) to flash box and PC 5. After the USB cable was connected the files which are transferred will appear on the Message window.
Fault tree: Changing pcb / changing EEPROM / Fault "E1" Fault type: 1 Changing pcb Fault type: 2 Unit displays "E1" Fault type: 3 New EEPROM to be connected to pcb with unknown SW version or software version before C1-06-05 Software update Isolate unit from power supply (Disconnect control fuses) Fault type: 2 or 3 Fault type: 1 Replace pcb, do NOT connect EEPROM as software version on new pcb might not be known NOTE: Do NOT connect replacement EEPROM to pcb as software version on pcb might be too
How to update CM units via PC To update a CM unit of new generation you have to use a software called „Megaload“. To install the Software on your PC, you just have to excecute the “Setup.exe” and follow the installation instructions on your screen. After Megaload installation please proceed as follows: 1. Save CM Software i.e. C-1-06.05. hex into a specific directory on your PC, (i.e. desktop) 2. Run Megaload 3. Basic settings of Megaload: Select software i.e. C1_06_05.hex Select Com port, i.e.
User instruction electrical descaler pump The descaler pump 60.70.409 (230V) and 60.70.497 (110V) must only be used to fill chemical part number: 6006.0110 into steam generators of equipment bearing either of the following marks on the data plate: S COMMON Warning! When working with chemicals, i.e.
User instruction electrical descaler pump 4. Lean the cabinet door close and fill the above mentioned quantity of descaler at 10 sec intervals into the steam generator NOTE: Descaling liquid can react very violently with the scale inside the steam generator! Should any foam appear at the steam inlet port stop filling and wash the interior cabinet with fresh water. 5. After filling the required quantity remove the hose from the steam inlet port.
RATIONAL INSTALLATION / COMMISSIONING CHECKLIST SCC / CM To be completed individually for each Rational Combi installation. S COMMON This checklist has to be completed and returned within 14 days of installation / commission to validate warranty.
PERIMETER CLEARANCES All units Left side minimum 50mm (2”) Left side 201/202 electric unit min. 500 mm (20“) Left side recommended for all units for service or with adjacent heat source 500 mm (20“) Rear side 50mm (2”) Right side 50mm (2”) Measured space Drain connection YES NO S Levelling and Floor fixing (observe local codes!) COMMON Steam temperature resistant pipe (I.e. Part # 8720.
Electrical connection – Observe Local and National Codes! Connected voltage L1 – L2 L1 – L3 L2 – L3 L1 - N L2 - N L3 - N N - Ground Volt Volt Volt Volt Volt Volt Volt YES S NO COMMON Ground connection to mains distribution panel? IMPORTANT!! Does indicated voltage on the unit data correspond with the measured voltage? 3 phase breaker installed? Breaker accessible from front by operator? Breaker size / Fuse rating A Nominal Amp draw per phase Electric units A 6 x 1/1 6 x 2/1 10 x 1/1 10 x 2/1 20 x
Yes NO Min. required gas flow pressure for all unit sizes when: All gas units are ON in the kitchen Natural Gas (49-58MJ/m3) 1,7-2,5 Kpa G20 17-25 mbar 6,7-10” w.c. 0,25-0,37psi Natural Gas (42-48MJ/m3) 2,0-3,0 Kpa G25 20-30 mbar 6,7-10” w.c. 0,25-0,37psi LPG 2,5-6,5 Kpa G30/31 25-65 mbar 10-25” wc 0,36–0,95psi Measured gas line flow pressure with all gas components in the kitchen (incl. Combi) on high flame.
Preventive Maintenance SCC/CM Customer: Address Street: City: Area (Zip) Code: Unit Serial Number: S COMMON Preventative Maintenance Work Scope: According Installation manual? Yes No 1.Installation Placement Water Connection Manufacturer: Type: Water Treatment Sedimentfilter Drain Gas Connection Electrical Connection 2.Door Function o.k. Faulty Comments: Function o.k. Faulty Comments: Function o.k.
Preventative Maintenance SCC 4. Bottom Group Function o.k. Faulty Comments: Water Connections leak tight Hand Shower+Shower hose (Function - non leaking) Retracting mechanism Drain gasket Floor model S COMMON Drain Connection Quenching / Drain box Drain valve SCC 5. Gas Specific parts Function o.k.
Inspections List 8. Control Panel Function o.k. Faulty Comments: Function o.k. Faulty Comments: Function o.k. Faulty Comments: Control Panel Gasket Control Panel Dials Mode Switch Temperatur Control S COMMON Timer function Core probe function LED-Indicators PCB Visual Check 9. Function Test Function test (Steam, Hot air, Combi etc.
Notes: COMMON S -107-
Water info Because of continuous examinations of systems for water treatment we would like to offer you a few information on some different systems. The given statements are only related to Rational units. If you already have made experiences with systems for water treatment, we would be very thankful if you could send us a short fax about your experiences. 1. Recommended systems for water treatment: S COMMON A)With pure scale problems in the steam generator we recommend hydrogen-(H+)Ionic exchanger.
Notes: COMMON S -109-
SCC Fault list - Troubleshooting S COMMON 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Page: 97 98 99 100 101 102 103 104 105 106 106 107 Service 10 Service 11 Service 25 Service 26 - 27 Gas - Service 34 No Function No Steam PCB change Gas - Reset, Polarity Descaling Service 12 Buzzer sounds CM Fault list - Troubleshooting 1. 2. 3. 4. 5. 6.
Service 10 Level electrode of the steam generator did not recognise a reduction of the water level during last SC-Automatic Info Unit shows Service 10 Activate function test Select step 8 SC Pump M4 and touch "Start" key Short circuit level electrode or check drain system and quenching box for dirt, clean if necessary yes no no Check pump for scale deposits or other dirt, that blocks the impeller 230V output at I/O-pcb X18 1/2 during function test? yes Check cable, connector and pump.
Indication Service 11 shown every time unit is switched on Actual measured filling volume above reference volume of steam generator Info Water supply from CDS to steam generator leaking Eliminate leak yes no Fault List SCC S Service 11 Check valve in the water supply line to the steam generator.
Service 25 Indication Service 25 every time unit is switched on CleanJet pump does not or not enough deliver enough water (loss of pressure during CleanJet). Typical indication: The running time of the program will be exceeded. Info Water supply sufficient? Check water filter, pressure, supply line. no yes Is cabinet door leak tight? Check door gasket and trolley gasket (only floor models). Check door for correct adjustment no yes Activate CleanJetPump (M6) in the function test.
Indication Service 26 every time unit is switched on Micro switch ball valve in permanent closed position. Unit out of order Info Activate ball valve in the function test. Output voltage at I/O pcb X25 7/8 (12V DC) present? no Change I/O pcb yes Fault List SCC S Service 26 Check motor ball valve, micro switch, cable, connector. Complete ball valve unit must be changed. Service 27 Indication Service 27 every time unit is switched on Micro switch ball valve in permanent open position.
Service 34 Indication Service 34.1 up to 34.16 every time unit is switched on Is Service 34.1 indicated and the yellow LED on the I/O pcb is flashing? Info yes Bus failure Indication of the faulty knot with the following code (combination of different faults possible): - 1: I/O pcb - 2: Bottom motor - 4: Top motor - 8: Top ignition box - 16: Bottom ignition box Are all dip switches set to "off"? yes Check I/O pcb.
No function Power supply ok? no Check main fuse of the power supply and earth leakage breaker no Replace defective part and find reason for tripping yes Fuse F1/F2 and contactor K1 ok? yes Press dry up protector of steam generator yes Is unit on now Check steam heating elements, SSR, water supply, scale build up no Fault List SCC S No function - safety chain Press safety thermostat of interior cabinet yes Is unit on now Check SSR, hot air heating element no Is main switch S1 working? C
No or to low steam production Humid cooking mode is selected but no/not enough steam is visible ATTENTION: Steam above 110°C is not visible, it does not condensate on the cabinet door! Info Door closed ? Close door, check door contact switch no yes no Is the water tap symbol flashing on the display? Has steam production failed completely Indication Service 14? or sensor steam generator defect? yes Check level electrode, osmosis water supply (check water quality), Check sensor steam generator wit
Changing pcb (pcb defectice) Standard Software update EEPROM Data faulty (no display of serial number, type) Service 17 Green LED on main pcb ON? Service 16 (from software 01-0 Isolate unit from power supply (Disconnect control fuses) Yes NO check pcb transformer primary and secondary voltage (12VAC) and plug connectors changing pcb EEPROM data faulty replace pcb, do NOT connect EEPROM disconnect old EEPROM Fault List SCC S Changing SCC pcb / changing SCC EEPROM / Software update Reconnect uni
"RESET" indication (Gas units) Unit shows "RESET" Does the connected gas type comply with the gas type on the name plate? INFO Reason: Flame monitoring does not work after ignition Convert unit to connected gas type.
Unit shows "Descaling of steam generator necessary" (Indication comes up every time unit is switched on and remains for 2 minutes) Info Is additionally Service 12 shown? yes Steam generator scaled up CDS display shows 9 red bars CDS-Sensor does not create pulses Check CDS-Sensor, cable and connector. no Touch function key: degree of scale is shown Activate and run descaling program.
Buzzer sounds Buzzer sounds for 30 seconds after fault identification and every time unit is switched on. Indication Service 20? Reason: Any thermo couple is defective Different buzzer intervals depending which thermo couple is defective Info yes Interior cabinet sensor B1 defective unit out of order no Indication CT probe defect? yes - More than 3 measuring points of the probe are defective.
No function Power supply ok No Check main fuse of the power supply and earth leakage breaker No Replace defective part and find reason for tripping Yes Fuses F1/F2 and contactor K1 ok? Yes Press dry up protector of steam generator Is unit on now? Yes Check steam heating elements, SSR, water supply, scale build up No Fault List CM S No function - safety circuit Press safety thermostat of interior cabinet Is unit on now? Yes Check SSR, hot air heating element No No Check cable and connect
No steam Wet cooking mode is activated but no steam is visible ATTENTION: Steam above 110°C is not visible, it does not condensate on the cabinet door! Info Door closed? No Close door and/or check door contact switch Yes No Yes Indication E6 or E4? Water tap open? Sediment filter at water connection to unit clean? No S Indication E16 or E17? Yes No Check level electrode S2 with Diagnostic program (dP 8) Indication = " 1 "? Unit connected to treated water? Yes E6: Check sensor steamgenerator B5
Fault type: 1 Changing pcb Fault type: 2 Unit displays "E1" Fault type: 3 New EEPROM to be connected to pcb with unknown SW version or software version before C1-06-05 Software update Isolate unit from power supply (Disconnect control fuses) Fault type: 2 or 3 Fault type: 1 Replace pcb, do NOT connect EEPROM as software version on new pcb might not be known Fault List CM S Fault tree: Changing pcb / changing EEPROM / Fault "E1" NOTE: Do NOT connect replacement EEPROM to pcb as software version
Buzzer sounds Buzzer sounds intermittently after fault identification and after switching on the unit. Indication E 7? Info Yes Reason of fault: Any thermo couple is defective Thermo couple of pcb defective, change pcb No Indication E3 or E4 or E5 or E6? E3 = Interior cabinet sensor B1 E4 = Quenching sensor B2 E5 = Core temp. sensor B3 E6 = Sensor steam generator B5 Unit out of order Fault List CM S Check connector of thermocouple for sufficient contact. Change defective thermocouple.
Level electrode of the steam generator did not recognise a reduction of the water level during last SC-Automatic INFO Unit shows E13 Activate function test Select step F14 SC Pump M4 by pressing timer key, activate function with core temper.
Indication "rES" (= reset) Unit shows "rES" Does the connected gas type comply with the gas type on the name plate? Reason: Flame monitoring does not work after ignition INFO - Convert unit to connected gas type.
Notes: S COMMON -128-
Notes: COMMON S -129-
Deckblatt Elektrische Dokumentation, Cover sheet for electrical Documentation Die Elektrische Dokumentation besteht aus: 1. diesem Deckblatt, 2. dem Schaltplan und 3. der Legende der elektrischen Bauteile The electric documentation contains: 1. this cover sheet, 2. the wiring diagram and 3. the bill of electrical material (BOM) Deckblatt-Nr. Front Page No.
0 1 2 3 4 5 6 7 8 9 MODUL 7 Option Options Blatt 7 Page MODUL 6 Summer, EEPROM Buzzer, EEPROM MODUL 3 Klima Plus, Fühler Humidity control, Sensors Blatt 6 Page Blatt 3 Page A4 0 MODUL 2 Heißluftheizung/Dampfheizung Hot air heating/Steam heating PCB MODUL 5 Lüftermotor Fan Motor, Cooling Fan Blatt 5 Page Blatt 2 Page MODUL 1 Sicherheitskette, Sp.
0 1 2 3 4 5 6 7 8 9 K1:1 / 5.00 K1:3 / 2.00 K1:5 / 2.00 N / 5.00 PE / 5.00 A4 S1Ein/Aus Schalter PCB On/off switch L1 X7 F6.1 F6 2AT . 2AT . L2 1 2 H1 F3 Sicherheitstemperaturbegrenzer 360°C/680°F Safety temperature limiter F4 1 W17 K1 14 N/O 13 T1 A1 K1 A2 X58 F5 0,8A .
PCB 6 1 2 3 4 5 6 7 8 W1 WH WH WH WH GY GY GY GY W16 -D1 -D2 X24 +D1 K1:3 / 1.08 K1:1 / 5.00 K1:5 / 1.
Version 76-00011 0 3 GY WH WH 2 1 3 S2 B1 1 B2 5 4 3 2 MODUL 3 Klima Plus, Fühler Humidity control, Sensors 1 B3 4 3 2 1 1 2 YE/GN B5 1 2 3 PK 6 YE X27 GN X6 WH BN 2 GN 3 WH 1 GN 2 WH 4 X2 KT-Potentiometer CT-Potentiometer 2 X4 5 Türkontaktschalter Door contact switch 1 4 Thermoelement Dampfgenerator Thermocouple steam generator X73 3 Thermoelement Kerntemperatur Termocouple core temperature W5 X3 GN X12 WH A4 GN 2 Thermoelement Ablöschung Thermocouple que
0 1 3 4 5 6 8 9 PCB X19 W3 X18 3 1 4 2 WH BU WH BU 1 2 3 4 X30 Y1 A1 Y2 Magnetventil-Füllen Solenoid valve filling A2 76-00011 0 5 6 W4 1 2 WH BU 1 2 3 4 X31 MODUL 4 Wasser Water, Drain, CleanJet A1 A2 Magnetventil-Ablöschung Solenoid valve guenching system 0 Version 7 M4 M ~ SC-Pumpe SC-pump A4 2 CM101E 3NAC400V 50-60Hz Erstellt von Created by Datum Date Blatt Page PA 30.04.
0 1.08 / 2.00 / K1:1 1.08 / N 1.08 / PE 1 3 2 4 5 6 8 7 9 BK BU YE/GN 1.08 / K1:13 BN 1.08 / K1:A2 BU A4 PCB M1 M ~ A2 A1 M11 M 1~ A2 F20 6,3A A1 3 . F21 M5 M 1~ 6,3A .
0 A4 1 2 3 4 5 6 7 8 9 PCB X8 W9 X47 X50 1 2 WH WH 1 2 1 2 3 4 0 EEPROM 76-00011 Version 0 MODUL 6 Summer, EEPROM Buzzer, EEPROM Externe EPROM Summer Buzzer T2 CM101E 3NAC400V 50-60Hz Erstellt von Created by Datum Date Blatt Page PA 30.04.
0 1 3 4 5 6 7 8 9 PCB Sicotronic system Sicotronic system X23 5 6 Dunstabzug Extractor hood 1 2 3 6:Heizungsanforderung (b) 4 5:Eingang Sicotronic (c) 3 4:Gerät EIN (a) 2 3:Nullleiter (d) 1 2:Frei X20 1:Frei A4 2 0 76-00011 Version 0 MODUL 7 Option Options CM101E 3NAC400V 50-60Hz Erstellt von Created by Datum Date Blatt Page PA 30.04.
Positionsliste Bill of material Name Name Artikelnr. Item number Artikelbezeichnung A4 B1 B2 B3 B5 F1 F2 F3 42.00.004 40.00.395 40.00.287 40.01.603 40.00.291 4001.0224 4001.0224 40.01.329 F4 H1 K1 M1 M11 M4 M5 R1 R2 R4 S2 S3 S7 T1 T2 V1 V2 X20 Y1 Y2 Z1 W0 W1 W11 W16 W17 W3 W4 W5 W9 40.00.605 3024.0201 40.01.555 40.00.274 3101.1008 44.00.207 3101.1008 44.00.194 44.00.534 40.00.265 3002.0402 40.00.454 40.00.464 40.00.278 3006.0107 40.01.589 40.01.589 40.00.338 50.00.316 50.00.139 40.00.465 8801.0136 40.
PCB 6 1 2 3 4 5 6 7 8 W1 WH WH WH WH GY GY GY GY W16 -D1 -D2 X24 +D1 K1:3 / 1.08 K1:1 / 5.00 K1:5 / 1.
0 1 1.08 / 2. 00 / K 1: 1 BK 1.08 / N BU 1.08 / P E 2 3 5 4 6 7 A4 BN 6 5 4 3 BU 2 1 PCB - 250V 240V 230V 220V 208V 200V 0V 12V ~ 7 1.08 / K 1:A 2 9 YE /G N T4 1.08 / K 1:13 8 0V 2 1 M2 M1 X67 X59 unten down M ~ F2 0 6, 3A M5 oben top M ~ 3 6, 3A F2. 1 M 6, 3A . F2 0 3 F2. 1 2 6, 3A . 1 2 1 X 221 X22 T4 - 40.00.592 (200-250VAC / 12VDC) M5 - 40.00.
0 1 2 3 5 4 6 7 9 8 K1:1 / 5.00 K1:3 / 2.00 K1:5 / 2.00 N / 5.00 PE / 5.00 A4 S1 Ein/Aus Schalter PCB On/o switch L1 X16 X7 F6.1 F6 2AT . 2AT . L2 11 PE 1 F4 X46 2 11 22 33 11 22 33 44 X56 F5 BK BN 12V 0V X57 F1 12V Steuertrafo Control transformer 200V T1 A2 11,5V A1 K1 13 208V 14 11,5V K1 N/O 220V W17 2,5V 0 230V 1,6A .
Deckblatt Elektrische Dokumentation, Cover sheet for electrical Documentation Die Elektrische Dokumentation besteht aus: 1. diesem Deckblatt, 2. dem Schaltplan und 3. der Legende der elektrischen Bauteile The electric documentation contains: 1. this cover sheet, 2. the wiring diagram and 3. the bill of electrical material (BOM) Deckblatt-Nr. Front Page No.
0 1 2 3 4 5 6 7 8 9 MODUL 7 Option Options Blatt 7 Page MODUL 6 Summer, EEPROM Buzzer, EEPROM MODUL 3 Klima Plus, Fühler Humidity control, Sensors Blatt 6 Page Blatt 3 Page A4 0 MODUL 2 Heißluftheizung/Dampfheizung Hot air heating/Steam heating PCB MODUL 5 Lüftermotor Fan Motor, Cooling Fan Blatt 5 Page Blatt 2 Page MODUL 1 Sicherheitskette, Sp.
0 1 3 2 5 4 6 8 7 9 K1:1 / 5.00 K1:3 / 5.00 PE / 2.00 A4 S1 Ein/Aus Schalter PCB On/off switch X7 1 3 F3 Sicherheitstemperaturbegrenzer 360°C/680°F Safety temperature limiter F4 1 2 RD 1 BK BN F2 6,3A 1 3 Z1 13 .00 4 .00 14 .05 200V 0V 0V 208V A2 220V T1 A1 K1 14 F5 0,8A . 230V 13 6,3A BU 2 12V K1 N/O X58 F1 BU 240V BU BK X13 Garraumbeleuchtung Interior cabinetlight 1 2 0 W17 BN 250V 4 W11 Halogentrafo Halogen transformer 2 2AT .
0 1 2 3 4 5 6 7 8 9 1.08 / K1:14 BN M5:~ / 5.00 1.08 / K1:A2 BU M5:N / 5.00 1.09 / PE PE / 5.00 YE/GN 1.08 / K1:A1 RD W17 W17 W17 A5/PCB / 5.01 A5/M1 / 5.
Version 76-00050 0 3 GY WH WH 2 1 3 S2 B1 1 B2 5 4 3 2 MODUL 3 Klima Plus, Fühler Humidity control, Sensors 1 B3 4 3 2 1 1 2 YE/GN B5 1 2 3 PK YE X27 GN X6 WH BN 2 GN 3 WH 1 GN 2 WH 4 X2 6 KT-Potentiometer CT-Potentiometer 2 X4 5 Türkontaktschalter Door contact switch 1 4 Thermoelement Dampfgenerator Thermocouple steam generator X73 3 Thermoelement Kerntemperatur Termocouple core temperature W5 X3 GN X12 WH A4 GN 2 Thermoelement Ablöschung Thermocouple que
0 1 3 4 5 6 8 9 PCB X19 W3 X18 3 1 4 2 WH BU WH BU 1 2 3 4 X30 Y1 A1 Y2 Magnetventil-Füllen Solenoid valve filling A2 76-00050 0 5 6 W4 1 2 WH BU 1 2 3 4 X31 MODUL 4 Wasser Water, Drain, CleanJet A1 A2 Magnetventil-Ablöschung Solenoid valve guenching system 0 Version 7 M4 M ~ SC-Pumpe SC-pump A4 2 CM 101/102 G 1NAC230V 50-60Hz Erstellt von Created by Datum Date Blatt Page PA 30.04.
0 1 1.09 / K1:1 BK 1.09 / K1:3 BU 2.08 / PE 3 2 4 5 6 8 7 9 GN/YE 2.08 / M5:~ BN 2.08 / M5:N BU A4 PCB . M1 M ~ A2 A1 M11 M 1~ A2 F20 6,3A A1 3 . F21 M5 M 1~ . . 6,3A . 2 1 X22 RJ 45 RJ 45 0 2.08 / A5/M1 2.
0 A4 1 2 3 4 5 6 7 8 9 PCB X8 W9 X47 X50 1 2 WH WH 1 2 1 2 3 4 0 EEPROM 76-00050 Version 0 MODUL 6 Summer, EEPROM Buzzer, EEPROM Externe EPROM Summer Buzzer T2 CM 101/102 G 1NAC230V 50-60Hz Erstellt von Created by Datum Date Blatt Page PA 30.04.
0 1 A4 2 3 4 5 6 7 8 9 PCB X23 Dunstabzug Extractor hood 1 2 3 0 76-00050 Version 0 MODUL 7 Option Options CM 101/102 G 1NAC230V 50-60Hz Erstellt von Created by Datum Date Blatt Page PA 30.04.
Positionsliste Bill of material Name Name Artikelnr. Item number Artikelbezeichnung A4 A5 B1 B2 B3 B5 F1 F2 F3 42.00.004 74.00.221 40.01.097 40.00.287 40.01.603 40.01.095 4001.0224 4001.0224 3014.0328 F4 H1 K1 M1 M11 M4 M5 M8 M9 S2 S3 S7 T1 T2 Y1 Y2 Z1 W0 W11 W14 W15 W17 W18 W3 W4 W5 W9 40.01.482 3024.0201 40.00.451 40.00.274 3101.1008 44.00.207 3101.1008 70.00.028 70.00.028 44.00.287 40.00.454 40.00.464 40.00.278 3006.0107 50.00.316 50.00.139 40.01.483 40.01.596 40.00.222 40.00.230 40.00.215 40.00.
0 1 2 3 5 4 6 7 8 9 1.08 / K 1:14 BN T4:~ / 5.00 1.08 / K 1:A 2 BU T4:N / 5.00 YE /G N P E / 5. 00 1.09 / P E 1.08 / K 1:A 1 RD W17 W17 W17 W17 W17 A6/M2 / 5. 01 A5/P C B / 5. 01 A5/M1 / 5.
0 1 2 1.09 / K 1:1 BK 1.09 / K 1:3 BU 2.08 / P E 3 5 4 6 7 A4 BN 6 5 4 3 BU 2 1 PCB - 250V 240V 230V 220V 208V 200V 0V 12V ~ 7 2.08 / T4:N 9 GN /Y E T4 2.08 / T4:~ 8 0V . 2 1 M1 X67 M2 X59 unten down M ~ 6, 3A M5 oben top M ~ F2 0 3 6, 3A F2. 1 M . . 6, 3A . F2 0 3 F2. 1 2 1 . . X22 6, 3A . 2 1 X 221 RJ 4 5 RJ 4 5 RJ 4 5 RJ 4 5 0 2.08 / A 5/M1 2.08 / A 6/M2 2.08 / A 5/PC B T4 - 40.00.592 (200-250VAC / 12VDC) M5 - 40.00.
Positionsliste Bill of material Name Name Artikelnr. Item number Artikelbezeichnung A4 A5 A6 B1 B2 B3 B5 F1 F2 F3 42.00.004 74.00.221 74.00.221 40.01.099 40.00.398 40.00.298 40.01.095 4001.0224 4001.0224 3014.0328 F4 H1 H2 K1 M1 M10 M2 M4 M5 M8 M9 S2 S3 S7 T1 T2 T4 Y1 Y2 Z1 W0 W11 W12 W14 W15 W17 W18 W3 W4 40.01.482 3024.0201 3024.0201 40.00.451 40.00.274 70.00.028 40.00.274 44.00.207 40.00.474 70.00.028 70.00.067 44.00.287 40.00.454 40.00.464 40.00.333 3006.0107 40.00.592 50.00.316 50.00.139 40.01.
Positionsliste Bill of material Name Name Artikelnr. Item number Artikelbezeichnung W5 W9 40.01.542 40.00.212 Kabel:Niveauelektrode Kabel:Alarmsummer Änderungsdatum Erzeuger 2004-04-19 16:21:09 SCHD Name Spannung Item description Module Modul Cable water level sensor Cable Buzzer Modul 3 Modul 6 CM202G 1NAC230V 50-60Hz Seite 2 von 2 Dokument-Nr.
Deckblatt Elektrische Dokumentation, Cover sheet for electrical Documentation Die Elektrische Dokumentation besteht aus: 1. diesem Deckblatt, 2. dem Schaltplan und 3. der Legende der elektrischen Bauteile The electric documentation contains: 1. this cover sheet, 2. the wiring diagram and 3. the bill of electrical material (BOM) Deckblatt-Nr. Front Page No.
0 1 2 3 4 5 A3 6 7 A2 Blatt 3 Page 9 MODUL 7 Option Options CPU MODUL 3 Klima Plus, Fühler Humidity control, Sensors 8 Blatt 7 Page MODUL 6 Garraumbeleuchtung, Summer, Zentrales Einstellrad, EEPROM Cabinet light, Buzzer, Central Dial, EEPROM Blatt 6 Page OPERATOR PCB 0 MODUL 5 Lüftermotor Fan Motor, Cooling Fan MODUL 2 Heißluftheizung/Dampfheizung Hot air heating/Steam heating Blatt 2 Page Blatt 5 Page A1 I/O-PCB MODUL 1 Sicherheitskette, Sp.
0 1 2 3 4 5 6 7 8 9 K1:1 / 5.00 K1:3 / 2.00 K1:5 / 2.00 N / 5.00 PE / 5.00 A2 Operator PCB F6 F6.1 S1Ein/Aus Schalter I/O-PCB A1 On/off switch L1 X10 X7 X14 2AT . X21 2AT . L2 1 2 W10 WH WH WH WH WH WH WH Sicherheitstemperaturbegrenzer 160°C/320°F Safety temperature limiter F3 X46 1 2 3 1 2 3 4 1 2 Sicherheitstemperaturbegrenzer 360°C/680°F Safety temperature limiter F4 1 F5 2 1,6A .
I/O-PCB 6 1 2 3 4 5 6 7 8 W1 WH WH WH WH GY GY GY GY W16 -D1 -D2 X24 +D1 K1:3 / 1.08 K1:1 / 5.00 K1:5 / 1.
Version 2 3 4 + M3 76-00003 0 X32 GY WH WH 2 1 3 YE/GN 4 M S2 W7 X29 2 3 GY GY GY 1 2 3 IN Signal P B1 B2 MODUL 3 Klima Plus, Fühler Humidity control, Sensors B4 3 2 1 B5 P1 1 2 3 4 5 SCC101E 3NAC400V 50-60Hz WH 4 BK 1 BN 2 BU 3 GN 4 RD 5 GY 1 GN 2 WH 3 GN 1 WH 2 Türkontaktschalter Door contact switch 1 W5 1 7 Fühler 6 Sensor 6 WH 4 X6 Fühler 5 Sensor 5 WH 3 X5 6 Fühler 4 Sensor 4 WH 2 X4 Fühler 3 Sensor 3 WH 1 X3 Fühler 2 Sensor 2 4 X1 5
Version 76-00003 0 X25 3 WH PE WH 1 2 3 GND Signal W6 X45 X30 1 2 WH 1 S12 IN S11 7 8 WH WH WH 2 3 4 3 4 5 6 - M MODUL 4 Wasser Water, Drain, CleanJet W3 Y1 A1 A2 6 X19 X31 4 1 5 2 6 3 WH BU WH BU WH BU 1 2 3 4 5 6 Y2 A1 A2 Y3 A1 A2 W4 M4 M ~ Kondensator C1 2,5µF Capacitor Umwälzpumpe Reinigung Cleanjet circulation pump 1 5 SC-Pumpe SC-pump X28 2 4 Magnetventil-Beschwadung Solenoid valve moistening X15 3 Magnetventil-Ablöschung Solenoid valve guenching syste
0 1.08 / 2.00 / K1:1 1.08 / N 1.08 / PE 1 3 2 4 5 6 8 7 9 BK BU YE/GN 1.08 / K1:13 BN 1.08 / K1:A2 BU A1 A2 I/O-PCB Operator PCB M1 M ~ A2 A1 M11 M 1~ A2 F20 6,3A A1 3 . F21 M5 M 1~ 6,3A .
0 1 2 A1 3 4 5 A2 I/O-PCB X49 X8 1 2 BN BU 1 2 7 8 9 Operator PCB X13 W11 6 W9 X47 X9 1 2 WH WH 1 2 X50 1 2 3 4 5 6 1 2 3 4 0 EEPROM 76-00003 Version 0 MODUL 6 Garraumbeleuchtung, Summer, Zentrales Einstellrad, EEPROM EEPROM S6 Zentrales Einstellrad Central dial T2 Summer Buzzer Garraumbeleuchtung Interior cabinetlight H1 SCC101E 3NAC400V 50-60Hz Erstellt von Created by Datum Date Blatt Page PA 05.05.
0 1 3 Sicotronic system Sicotronic system X23 5 5 6 6 7 8 9 Operator PCB Dunstabzug Extractor hood 1 2 3 6:Heizungsanforderung (b) 4 5:Eingang Sicotronic (c) 3 4:Gerät EIN (a) 2 3:Nullleiter (d) 1 2:Frei X20 4 A2 I/O-PCB 1:Frei A1 2 0 76-00003 Version 0 MODUL 7 Option Options SCC101E 3NAC400V 50-60Hz Erstellt von Created by Datum Date Blatt Page PA 05.05.
Positionsliste Bill of material Name Name Artikelnr. Item number Artikelbezeichnung A1 A2 B1 B2 B4 B5 B6 F1 F2 F3 40.00.049 42.00.002 40.00.395 40.00.287 40.00.290 40.00.291 40.01.604 4001.0224 4001.0224 40.01.329 F4 H1 K1 M1 M11 M3 M4 M5 M6 P1 R1 R2 R4 S1 S11 S2 S3 S4 S6 T1 T2 V1 V2 X20 Y1 Y2 Z1 W0 W1 40.00.605 3024.0201 40.01.555 40.00.274 3101.1008 3101.1010 44.00.207 3101.1008 56.00.185 3017.1011 44.00.194 44.00.534 40.00.265 TEXT 44.00.211 3002.0402 40.00.335 3016.0102 40.00.404 40.00.277 3006.
Positionsliste Bill of material Name Name Artikelnr. Item number Artikelbezeichnung W10 W11 W13 W16 W17 W2 W3 W4 W5 W7 W8 W9 40.00.210 40.00.211 40.00.213 40.00.232 40.01.297 40.00.202 40.00.203 40.00.204 40.00.205 40.00.207 40.00.208 40.00.
I/O-PCB 6 1 2 3 4 5 6 7 8 W1 WH WH WH WH GY GY GY GY W16 -D1 -D2 X24 +D1 K1:3 / 1.08 K1:1 / 5.00 K1:5 / 1.
0 1 1.08 / 2. 00 / K 1: 1 BK 1.08 / N BU 1.08 / P E 2 3 5 4 6 7 A1 BN 6 5 4 3 BU 2 1 A2 I/O-PCB O perator P C B - 250V 240V 230V 220V 208V 200V 0V 12V ~ 7 1.08 / K 1:A 2 9 YE /G N T4 1.08 / K 1:13 8 0V 2 1 M2 M1 X67 X59 unten down M ~ F2 0 6, 3A M5 oben top M ~ 3 6, 3A F2. 1 M 6, 3A . F2 0 3 F2. 1 2 6, 3A . 1 2 1 X 221 X22 T4 - 40.00.592 (200-250VAC / 12VDC) M5 - 40.00.
Deckblatt Elektrische Dokumentation, Cover sheet for electrical Documentation Die Elektrische Dokumentation besteht aus: 1. diesem Deckblatt, 2. dem Schaltplan und 3. der Legende der elektrischen Bauteile The electric documentation contains: 1. this cover sheet, 2. the wiring diagram and 3. the bill of electrical material (BOM) Deckblatt-Nr. Front Page No.
0 1 2 3 4 5 A3 6 7 A2 Blatt 3 Page 9 MODUL 7 Option Options CPU MODUL 3 Klima Plus, Fühler Humidity control, Sensors 8 Blatt 7 Page MODUL 6 Garraumbeleuchtung, Summer, Zentrales Einstellrad, EEPROM Cabinet light, Buzzer, Central Dial, EEPROM Blatt 6 Page OPERATOR PCB 0 MODUL 5 Lüftermotor Fan Motor, Cooling Fan MODUL 2 Heißluftheizung/Dampfheizung Hot air heating/Steam heating Blatt 2 Page Blatt 5 Page A1 I/O-PCB MODUL 1 Sicherheitskette, Sp.
0 1 2 3 4 5 6 7 8 9 K1:1 / 5.00 K1:3 / 5.00 PE / 2.00 A2 Operator PCB F6 F6.1 S1Ein/Aus Schalter I/O-PCB A1 On/off switch X10 X7 3 2 1 2 3 1 2 3 4 W10 WH WH WH WH WH WH WH X46 1 2 3 1 2 3 4 2AT . X21 1 2 Sicherheitstemperaturbegrenzer 135°C/275°F Safety temperature limiter F3 Sicherheitstemperaturbegrenzer 360°C/680°F Safety temperature limiter F4 W13 1 2 X56 RD BK BU GN/YE GY 1 2AT .
0 1 2 3 4 5 6 7 8 9 1.09 / K1:14 BN M5:~ / 5.00 1.09 / K1:A2 BU M5:N / 5.00 1.09 / PE PE / 5.00 YE/GN 1.09 / K1:A1 RD W17 W17 W17 A5 / I/O-PCB / 5.01 A5/M1 / 5.
Version 2 3 4 + M3 76-00006 0 X32 GY WH WH 2 1 3 YE/GN 4 M S2 W7 X29 2 3 GY GY GY 1 2 3 IN Signal P B1 B2 MODUL 3 Klima Plus, Fühler Humidity control, Sensors B4 3 2 1 B5 P1 1 2 3 4 5 SCC 101/102 G 1NAC230V 50-60Hz WH 4 BK 1 BN 2 BU 3 GN 4 RD 5 GY 1 GN 2 WH 3 GN 1 WH 2 Türkontaktschalter Door contact switch 1 W5 1 7 Fühler 6 Sensor 6 WH 4 X6 Fühler 5 Sensor 5 WH 3 X5 6 Fühler 4 Sensor 4 WH 2 X4 Fühler 3 Sensor 3 WH 1 X3 Fühler 2 Sensor 2 4
Version 76-00006 0 X25 3 WH PE WH 1 2 3 GND Signal W6 X45 X30 1 2 WH 1 S12 IN S11 7 8 WH WH WH 2 3 4 3 4 5 6 - M MODUL 4 Wasser Water, Drain, CleanJet W3 Y1 A1 A2 6 X19 X31 4 1 5 2 6 3 WH BU WH BU WH BU 1 2 3 4 5 6 Y2 A1 A2 Y3 A1 A2 W4 M4 M ~ Kondensator C1 2,5µF Capacitor Umwälzpumpe Reinigung Cleanjet circulation pump 1 5 SC-Pumpe SC-pump X28 2 4 Magnetventil-Beschwadung Solenoid valve moistening X15 3 Magnetventil-Ablöschung Solenoid valve guenching syste
0 1 1.09 / K1:1 BK 1.09 / K1:3 BU 2.08 / PE 3 2 4 5 6 8 7 9 GN/YE 2.08 / M5:N BU A1 A2 I/O-PCB . . RJ 45 BN RJ 45 2.08 / M5:~ Operator PCB . M1 M ~ A2 A1 M11 M 1~ A2 F20 6,3A A1 3 . F21 M5 M 1~ . . 6,3A . 2 1 X22 RJ 45 0 2.08 / A5/M1 2.
0 1 2 A1 3 4 5 A2 I/O-PCB X49 X8 1 2 BN BU 1 2 7 8 9 Operator PCB X13 W11 6 W9 X47 X9 1 2 WH WH 1 2 X50 1 2 3 4 5 6 1 2 3 4 0 EEPROM 76-00006 Version 0 MODUL 6 Garraumbeleuchtung, Summer, Zentrales Einstellrad, EEPROM EEPROM S6 Zentrales Einstellrad Central dial T2 Summer Buzzer Garraumbeleuchtung Interior cabinetlight H1 SCC 101/102 G 1NAC230V 50-60Hz Erstellt von Created by Datum Date Blatt Page PA 05.05.
0 1 2 3 A1 I/O-PCB 4 5 6 7 8 9 A2 Operator PCB X23 Dunstabzug Extractor hood 1 2 3 0 76-00006 Version 0 MODUL 7 Option Options SCC 101/102 G 1NAC230V 50-60Hz Erstellt von Created by Datum Date Blatt Page PA 05.05.
Positionsliste Bill of material Name Name Artikelnr. Item number Artikelbezeichnung A1 A2 A5 B1 B2 B4 B5 B6 F1 F2 F3 40.00.049 42.00.002 74.00.221 40.01.097 40.00.287 40.00.290 40.01.095 40.01.604 4001.0224 4001.0224 3014.0328 F4 H1 K1 M1 M11 M3 M4 M5 M6 M8 M9 P1 S1 S11 S2 S3 S4 S6 T1 T2 Y1 Y2 Z1 W0 W10 W11 W13 W14 40.01.482 3024.0201 40.00.451 40.00.274 3101.1008 3101.1010 44.00.207 3101.1008 56.00.185 70.00.028 70.00.028 3017.1011 TEXT 44.00.211 44.00.287 40.00.335 3016.0102 40.00.404 40.00.
Positionsliste Bill of material Name Name Artikelnr. Item number Artikelbezeichnung W15 W17 W18 W2 W3 W4 W5 W7 W8 W9 40.00.215 40.01.300 40.00.237 40.00.202 40.00.203 40.00.247 40.00.205 40.00.207 40.00.208 40.00.
0 1 2 3 5 4 6 7 8 9 1.09 / K 1:14 BN T4:~ / 5.00 1.09 / K 1:A 2 BU T4:N / 5.00 YE /G N P E / 5. 00 1.09 / P E 1.09 / K 1:A 1 RD W17 W17 W17 W17 W17 A6 / I/O -P C B / 5.0 1 A6/M2 / 5. 01 A5/M1 / 5.
0 1 2 1.09 / K 1:1 BK 1.09 / K 1:3 BU 2.08 / P E 3 5 4 6 7 A1 5 4 3 BU 2 1 O perator P C B - 250V 240V 230V 220V 208V 200V 0V 12V 0V 2 . . RJ 4 5 6 A2 I/O-PCB RJ 4 5 BN ~ 7 2.08 / T4:N 9 GN /Y E T4 2.08 / T4:~ 8 . 1 M2 M1 X67 X59 unten down M ~ F2 0 6, 3A M5 oben top M ~ 3 6, 3A F2. 1 M . . 6, 3A . F2 0 3 F2. 1 2 1 . . X22 6, 3A . 2 1 X 221 RJ 4 5 RJ 4 5 RJ 4 5 0 2.08 / A 5/M1 2.08 / A 6/M2 2.08 / A 6 / I/O -P C B T4 - 40.00.
Notes: COMMON S -129-
SCC Service Reference 1 2 1 HACCP CleanJet 3 5 - activated 1 10:24 am/pm 24 h h:m m:s c 2 2 08/22/03 Start time Startzeit °C / °F 22.08.
Error code CM Service Reference 1 Cabinet display Time display H20 OPEn CHnG PoL open water tap change polarity of mains supply E1 2 3 4 5 6 Key code CM (SCC line) a: Cleaning program select Cool Down with "1" press key "5" for 10 sec. „CLEn“ is shown in temperature display press key "4" 1x; b: De-scaling program select Cool Down with "1" press key "5" for 10 sec.
RATIONAL Contact Germany RATIONAL-Service: Fax: +49 (0)8191-327397 e-mail: service@rational-online.de web: www.rational-ag.com Spare part order: Fax: +49 (0)8191-327408 e-mail: ersatzteile@rational-online.de RATIONAL- Chef Line: Telefon: +49 (0)8191-327300 Edition 11-2006 RATIONAL UK Tel: ++ 44-15 82-48 03 88 Fax: ++ 44-15 82-48 50 01 E-mail: rational@rational-uk.co.uk RATIONAL Ibérica Cooking Systems S.L. Tel: ++ 34-93-475 17 50 Fax: ++ 34-93-475 17 57 E-mail: rational@rationaliberica.