Operating instructions
Care, inspection, maintenance and repair
14 / 84
Warning!
Servicing the incoming air filter. The device automatically recognises when the air filter is
soiled. You receive a service message and a request to replace the air filter when the air filter
is soiled. The unit must not be operated without air filter. Please heed the following when
replacing the air filter:
Unit size 6x1/1 GN, 6x2/1 GN, 10x1/1 GN und die 10x2/1 GN
Air filter part number: 40.03.461
This air filter can be replaced by the user. When the air filter is replaced, the new air filter
must be inserted in the correct position. Please follow the instructions in the “Maintenance”
section on how to replace the air filter.
Unit size 20x1/1 GN und die 20x2/1 GN
This air filter can only be replaced by an authorised service partner.
Warning! The device’s water jet protection is only guaranteed with the filter and cover
completely mounted.