Datasheet

06 February 2012 Broadcom Europe Ltd. 406 Science Park Milton Road Cambridge CB4 0WW Page 83
© 2012 Broadcom Corporation. All rights reserved
Bit(s)
Field Name
Descri
ption
Type
Reset
31:25
Reserved
-
Write as 0, read as don't care
24 ACMD_ERR Create auto command error:
0 = no
1 = yes
RW 0x0
23
Reserved
-
Write as 0, read as don't care
22 DEND_ERR Create end bit on data line not 1:
0 = no
1 = yes
RW 0x0
21 DCRC_ERR Create data CRC error:
0 = no
1 = yes
RW 0x0
20 DTO_ERR Create timeout on data line:
0 = no
1 = yes
RW 0x0
19 CBAD_ERR Create incorrect command index in response:
0 = no
1 = yes
RW 0x0
18 CEND_ERR Create end bit on command line not 1:
0 = no
1 = yes
RW 0x0
17 CCRC_ERR Create command CRC error:
0 = no
1 = yes
RW 0x0
16 CTO_ERR Create timeout on command line:
0 = no
1 = yes
RW 0x0
15
Reserved
-
Write as 0, read as don't care
14 ENDBOOT Create boot operation has terminated:
0 = no
1 = yes
RW 0x0
13 BOOTACK Create boot acknowledge has been received:
0 = no
1 = yes
RW 0x0