Datasheet
06 February 2012 Broadcom Europe Ltd. 406 Science Park Milton Road Cambridge CB4 0WW Page 78
© 2012 Broadcom Corporation. All rights reserved
21 DCRC_ERR Set flag if data CRC error:
0 = no
1 = yes
RW 0x0
20 DTO_ERR Set flag if timeout on data line:
0 = no
1 = yes
RW 0x0
19 CBAD_ERR Set flag if incorrect command index in response:
0 = no
1 = yes
RW 0x0
18 CEND_ERR Set flag if end bit on command line not 1:
0 = no
1 = yes
RW 0x0
17 CCRC_ERR Set flag if command CRC error:
0 = no
1 = yes
RW 0x0
16 CTO_ERR Set flag if timeout on command line:
0 = no
1 = yes
RW 0x0
15
Reserved
-
Write as 0, read as don't care
14 ENDBOOT Set flag if boot operation has terminated:
0 = no
1 = yes
RW 0x0
13 BOOTACK Set flag if boot acknowledge has been received:
0 = no
1 = yes
RW 0x0
12 RETUNE Set flag if clock retune request was made:
0 = no
1 = yes
RW 0x0
11:9
Reserved
-
Write as 0, read as don't care
8 CARD Set flag if card made interrupt request:
0 = no
1 = yes
RW 0x0
7:6
Reserved
-
Write as 0, read as don't care
5 READ_RDY Set flag if DATA register contains data to be
read:
0 = no
1 = yes
RW 0x0