21 DCRC_ERR Data CRC error:
0 = no error
1 = error
RW 0x0
20 DTO_ERR Timeout on data line:
0 = no error
1 = error
RW 0x0
19 CBAD_ERR Incorrect command index in response:
0 = no error
1 = error
RW 0x0
18 CEND_ERR End bit on command line not 1:
0 = no error
1 = error
RW 0x0
17 CCRC_ERR Command CRC error:
0 = no error
1 = error
RW 0x0
16 CTO_ERR Timeout on command line:
0 = no error
1 = error
RW 0x0
15 ERR An error has occured:
0 = no error
1 = error
RO 0x0
14 ENDBOOT Boot operation has terminated:
0 = no
1 = yes
RW 0x0
13 BOOTACK Boot acknowledge has been received:
0 = no
1 = yes
RW 0x0
12 RETUNE Clock retune request was made:
0 = no
1 = yes
RO 0x0
11:9
Reserved
-
Write as 0, read as don't care
8 CARD Card made interrupt request:
0 = no
1 = yes
RO 0x0
7:6
Reserved
-
Write as 0, read as don't care