Table 6-34 General Purpose Clocks Control
Clock Manager General Purpose Clock Divisors (CM_GP0DIV, CM_GP1DIV &
CM_GP2DIV)
Address 0x 7e10 1074 CM_GP0DIV
0x 7e10 107c CM_GP1DIV
0x 7e10 1084 CM_GP2DIV
Bit
Number
Field
Name
Description
Read/
Write
Reset
31-24 PASSWD
Clock Manager password “5a” W 0
23-12 DIVI
Integer part of divisor
This value has a minimum limit determined by the
MASH setting. See text for details. To avoid lock-ups
and glitches do not change this control while BUSY=1.
R/W 0
11-0 DIVF
Fractional part of divisor
To avoid lock-ups and glitches do not change this
control while BUSY=1.
R/W 0
Table 6-35 General Purpose Clock Divisors