User manual
Export 01.09.2017 Copyright by Joy-IT 6
3
Now you can start the calibraon tool:
You will now see 4 points on the display which needs to be pressed one aer another. Aer that, four
values will be printed which you need to use as new calibraon data. Example:
Please note that the four values at the „Calibraon“ opon may vary to yours. The rst value matches
to „MinX“, the second to „MaxX“, the third to „MinY“ and the fourth to „MaxY“. You need to create a
new le with the following command:
Enter the example above with your calibraon data.
The installaon is done aer saving and restarng.
JOY-iT 10.1“ Touchscreen-Display
sudo nano /usr/share/X11/xorg.conf.d/99-calibration.conf
sudo reboot
Section “InputClass“
Identifier “calibration“
MatchProduct “eGalax Inc. USB TouchController“
Option “Calibration“ “1979 65 1884 115“
Option “SwapAxes“ “0“
EndSection
xinput_calibrator