User manual

Export 01.09.2017 Copyright by Joy-IT 6
3
Now you can start the calibraon tool:
You will now see 4 points on the display which needs to be pressed one aer another. Aer that, four
values will be printed which you need to use as new calibraon data. Example:
Please note that the four values at the „Calibraon“ opon may vary to yours. The rst value matches
to „MinX“, the second to „MaxX“, the third to „MinY“ and the fourth to „MaxY“. You need to create a
new le with the following command:
Enter the example above with your calibraon data.
The installaon is done aer saving and restarng.
JOY-iT 10.1“ Touchscreen-Display
sudo nano /usr/share/X11/xorg.conf.d/99-calibration.conf
sudo reboot
Section “InputClass“
Identifier “calibration“
MatchProduct “eGalax Inc. USB TouchController“
Option “Calibration“ “1979 65 1884 115“
Option “SwapAxes“ “0“
EndSection
xinput_calibrator