Operating instructions

1
AGA YF 99
AGA "YELLOW FLAME"
12028 E. Philadelphia St. Whittier , CA 90601 U.S.A.
(562) 696-8718 FAX (562) 698-3510
E-Mail: gaslogs@riwinc.com Web http://www.riwinc.com
APPROVED
R
A s s e m b l y , I n s t a l l a t i o n , a n d O p e r a t i o n
I n s t r u c t i o n s f o r R a s m u s s e n " Y E L L O W F L A M E "
Natural and Propane Hearth Kit Models:
A18 Manual/Switch/Remote Control: (XF,PR,WS,LS 18)(EXF,ELS,EC 20)
(XF,WS,LS 21)-A18-M,S,R-(N,L)
A24 Manual/Switch/Remote Control: (EXF,XF,PR,WS,ELS,LS,EC 24)-
A24-M,S,R-(N,L)
A30 Manual/Switch/Remote Control: (EXF,XF,PR,WS,ELS,LS,EC 30)(PR 36)-
A30-M,S,R-(N,L)
THIS BURNER IS FOR USE FOR USE IN A FULLY
FUNCTIONING WOOD BURNING FIREPLACE
WITH THE DAMPER WIDE OPEN.
THE FLUE MUST VENT ALL PRODUCTS OF COMBUSTION.
.
THESE INSTRUCTIONS CONFORM TO ANSI Z21.60-1996/CGA 2.26-M96
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
WARNING:
Improper installation, adjustment,
alteration, service or maintenance can cause
property damage, personal injury or loss of life. Read
these instructions thoroughly before installation. For
assistance or additional information, consult your
gas log dealer, qualified installer, service agency or
gas supplier.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbors phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier,
call the fire department.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
.
INSTALLATION AND SERVICE: Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
.
IMPORTANT INFORMATION
1. This gas log set must be installed only in a solid-fuel burning fireplace with a working flue and constructed of non
combustible material. The flue must exhaust all products of combustion.
2. The minimum permanent free opening of the fireplace chimney or chimney damper must be at least (*Square
Inches - see ITEM 5 below) based on a minimum chimney height of at least 10 feet. The area of the flue must not
be less than 1/10 the area of the fireplace opening.
3. Solid fuels shall not be burned in a fireplace where a decorative appliance is installed.
4. The chimney damper must be fixed in a manner to maintain permanent free opening as outlined in item 2 above at
all times. To accomplish this, install the damper clamp (provided) on the edge of the damper blade to prevent its
closing or drill a hole or holes in the damper.