SPECIAL CONSIDERATIONS
Radiant Heat:
1. RI flooring can be installed over Radiant heating (hydroponic) systems.
There must be at least 1/2 inch of separation between the radiant
heat source and the RI flooring. The maximum temperature of the
subfloor surface must not exceed 85°. Before installing flooring
products over newly constructed radiant-heating systems, operate the
system at maximum capacity to force any residual moisture from the
cementitious topping of the radiant-heating system. Then set the
thermostat to a comfortable room temperature for the installation. For
existing systems, the system must be switched off for a minimum of
48 hours before, during and 48 hours after flooring installation. This is
the only type of radiant heat that is approved. Subfloors should have
been operational for at least 3 weeks prior to installation to drive out
moisture and calibrate temperature settings. All radiant heat floors
should be turned down so subfloor temperature is maintained at 65
degrees for 3 days prior to installation and kept at 65 degrees for at
least 48 hours after installation to allow the adhesive to fully cure.
Maximum operating temperature should never exceed 85°F.
2. Direct Sunlight: Installations in areas where there is heavy direct
sunlight exposure for long periods of time should utilize window
treatments.
3. Protecting New Installations: New Installations must be protected while
the adhesive cures. Early foot traffic, point or rolling loads can cause
adhesive displacement or breaking of the bond between the adhesive