Operation Manual
Rascal 600B/700B Owner’s Manual
EMC Part: 19278100 Rev. 3 ◦ 06/29/2009
38
Self-Centering Stabilizer Magnets
The magnets should be occasionally cleaned of metal filings or other metal
debris with a soft cloth. While cleaning avoid metal “splinters” from
penetrating your skin.
ILLUSTRATION 18 – Stabilizer Magnets
Clock Battery
After time, the clock may begin to lose time, or stop, when the battery runs
down. The battery is easily replaced by removing the clock from the dash
and prying open the clock’s case, then inserting a new battery. Use the
following steps to replace the clock battery:
• Remove clock from the dash.
• Use a small screwdriver to open the case by inserting the screwdriver
blade into the notch on the back cover. Gently twist blade so that the
back cover comes off.
• Slide the metal battery cover plate aside and remove battery.
• Install new battery with positive pole (+) facing outwards. Slide battery
cover back in place over new battery. After replacing battery, make sure
time setting is correct before replacing clock into dash.
Battery Types: SR626SW, UCC 377, Ray-O-Vac RW329
Electrical Connections
Check battery terminals and all plug connectors to make sure that a tight
connection is made. If battery terminals are corroded, disconnect the leads
and clean all connections with a soft wire brush. Reconnect leads and
apply a protective coating (e.g., petroleum jelly, etc.) to prevent corrosion.