STEP (E): Repeat Steps (B) and (D) for the Other Clusters
After finishing the upgrade of one cluster, continue to upgrade the
remaining clusters.
To upgrade the other clusters, repeat the following procedure on
each cluster
1. Disconnect the Cat5 cable attached with the USB-to-RS485 cable
from the HubPac cluster on which the upgrade has finished.
2. Reconnect the Cat5 cable to the server connection port of “another
cluster” on the same HubPac, as described in STEP (B): Connect
One Cluster of the HubPac to the PC (on page 177).
3. Click Send to
Paragon in the Paragon Update window to upgrade the
connected cluster. The procedure is the same as those described in
STEP (D): Launch the Paragon Update Utility (on page 183).
Upo
n upgrading 8 clusters successfully, the P2-HubPac firmware update
is complete.