User guide
Chapter 10: Configurations
150
Non-Standard Tiered Configurations
Non-Standard tiered configurations are those configurations supported by
Paragon II, but require special procedure in order to function properly.
These include:
• Triangle Configuration
• Single Diamond Configuration
• Redundant Configuration
FUNC Reset Guidelines for Reconnection
After any re-connection subsequent to the Non-Standard tiered
configuration, all Paragon switches should undergo a FUNC reset
to clear the database. See Reset Unit (on page 43) for more
informatio
n on clearing the database. This procedure should be
performed starting from the third-tier device down to the Base
Unit.
Whenever a third-tier Paragon switch is replaced, all of the
second-tier Paragon switches and Base Units should undergo a
FUNC reset.
Whenever a second-tier Paragon switch is replaced, all of the
Base Units should undergo a FUNC reset.
Whenever a base-tier Paragon switch (Base Unit) is replaced, only
the new Paragon switch should undergo a FUNC reset.