Chapter 6: Operation - User Functions
86
Choose a non-ACTIVATOR channel in the Selection Menu.
The FOLLOWER user stations' monitors remain showing the
FOLLOWER channel videos, while the keyboard and mouse
control is back on these user stations.
• Power cycle the desired user station(s), be it an ACTIVATOR or
FOLLOWER user station.
Note: If the user station is P2-USTIP, it automatically enters the
remote mode when quitting the Multiple Video mode. Press
Ctrl+Alt+Delete on the P2-USTIP if you want to return to the local
mode.
Limitation
• The function is not applicable to those channels which share only one
path via the tiered device, such as P2ZCIM, P2CIM-APS2-B or
P2CIM-AUSB-B (for IBM BladeCenter servers).
• For 16-channel associations, the associated channel ports must be on
the Base Unit if your Paragon system is a multi-tier configuration.
Messages on the ACTIVATOR User Station
The success or failure of data outputs from the FOLLOWER channel(s)
will be reported on the screen of the ACTIVATOR user station (see the
example images below).
The 1st FOLLOWER channel successfully outputs its data
The 2nd FOLLOWER channel successfully outputs its data
The 3rd FOLLOWER channel fails to output its data
Every FOLLOWER channel successfully outputs its data